Comparison of radiation exposure during transradial diagnostic coronary angiography with single‐ or multi‐catheters approach. Issue 2 (10th November 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of radiation exposure during transradial diagnostic coronary angiography with single‐ or multi‐catheters approach. Issue 2 (10th November 2016)
- Main Title:
- Comparison of radiation exposure during transradial diagnostic coronary angiography with single‐ or multi‐catheters approach
- Authors:
- Plourde, Guillaume
Abdelaal, Eltigani
MacHaalany, Jimmy
Rimac, Goran
Poirier, Yann
Arsenault, Jean
Costerousse, Olivier
Bertrand, Olivier F. - Abstract:
- Abstract : Objective: To compare radiation exposure during transradial diagnostic coronary angiography (DCA) using standard single‐ or multi‐catheters with different shapes. Background: Transradial DCA can be performed using single‐ or multi‐catheters to canulate left and right coronary ostia. To date, it remains unknown whether there are differences in radiation exposure between the two strategies. Methods: From November 2012 to June 2014, 3, 410 consecutive patients who underwent transradial DCA were recruited. Groups were based on the initial diagnostic catheter used and were dichotomized between single‐ and multi‐catheters approach. All crossovers were excluded. The multi‐catheters approach (Multi) group consisted of Judkins left and right catheters, whereas the single‐catheter (Single) group included Amplatz, Barbeau, or Multipurpose catheters. Fluoroscopy time (FT) as a surrogate end‐point for total radiation exposure and kerma‐area product (KAP; patient radiation exposure) were collected as radiation exposure parameters. Results: A single‐catheter strategy was used in 439 patients, while 2, 971 patients had a multi‐catheters approach. There was no significant difference in FT between groups (2.86 ± 1.48 min for Multi vs. 2.87 ± 1.72 min for Single, P = 0.13). The multi‐catheters approach was associated with a significant 15% reduction in KAP (3, 599 ± 2, 214 cGy · cm 2 vs. 3, 073 ± 1, 785 cGy · cm 2, P < 0.0001) compared to the single‐catheter approach. When poolingAbstract : Objective: To compare radiation exposure during transradial diagnostic coronary angiography (DCA) using standard single‐ or multi‐catheters with different shapes. Background: Transradial DCA can be performed using single‐ or multi‐catheters to canulate left and right coronary ostia. To date, it remains unknown whether there are differences in radiation exposure between the two strategies. Methods: From November 2012 to June 2014, 3, 410 consecutive patients who underwent transradial DCA were recruited. Groups were based on the initial diagnostic catheter used and were dichotomized between single‐ and multi‐catheters approach. All crossovers were excluded. The multi‐catheters approach (Multi) group consisted of Judkins left and right catheters, whereas the single‐catheter (Single) group included Amplatz, Barbeau, or Multipurpose catheters. Fluoroscopy time (FT) as a surrogate end‐point for total radiation exposure and kerma‐area product (KAP; patient radiation exposure) were collected as radiation exposure parameters. Results: A single‐catheter strategy was used in 439 patients, while 2, 971 patients had a multi‐catheters approach. There was no significant difference in FT between groups (2.86 ± 1.48 min for Multi vs. 2.87 ± 1.72 min for Single, P = 0.13). The multi‐catheters approach was associated with a significant 15% reduction in KAP (3, 599 ± 2, 214 cGy · cm 2 vs. 3, 073 ± 1, 785 cGy · cm 2, P < 0.0001) compared to the single‐catheter approach. When pooling all patients, mean FT was 2.86 ± 1.51 min. Mean KAP was 3, 141 ± 1, 854 cGy · cm 2 . Reference levels in our institution in both groups were below international diagnostic reference levels. Overall both FT and KAP decreased by 15% and 19%, respectively, over the 2‐year study period. Conclusions: Compared to a single‐catheter approach, a multi‐catheters approach with standard Judkins catheters for DCA significantly reduced patient radiation exposure. Whether single catheter designed for DCA by radial approach can further reduce radiation exposure compared to Judkins catheters remains to be compared in randomized studies. © 2016 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 90:Issue 2(2017)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 90:Issue 2(2017)
- Issue Display:
- Volume 90, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 90
- Issue:
- 2
- Issue Sort Value:
- 2017-0090-0002-0000
- Page Start:
- 243
- Page End:
- 248
- Publication Date:
- 2016-11-10
- Subjects:
- cardiac catheterization -- diagnostic catheters -- radiation exposure -- transradial
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.26851 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4464.xml