Normal Reference Values and z Scores of the Pulmonary Artery Acceleration Time in Children and Its Importance for the Assessment of Pulmonary Hypertension. (January 2017)
- Record Type:
- Journal Article
- Title:
- Normal Reference Values and z Scores of the Pulmonary Artery Acceleration Time in Children and Its Importance for the Assessment of Pulmonary Hypertension. (January 2017)
- Main Title:
- Normal Reference Values and z Scores of the Pulmonary Artery Acceleration Time in Children and Its Importance for the Assessment of Pulmonary Hypertension
- Authors:
- Koestenberger, Martin
Grangl, Gernot
Avian, Alexander
Gamillscheg, Andreas
Grillitsch, Marlene
Cvirn, Gerhard
Burmas, Ante
Hansmann, Georg - Abstract:
- Abstract : Background—: Pulsed-wave Doppler determination of the pulmonary artery acceleration time (PAAT) as a surrogate for pulmonary artery pressure was found to be of clinical value for assessment of pulmonary hypertension (PH) with studies to date exclusively performed in adults. This study aims to provide representative, normal reference values for PAAT in children of all ages. Moreover, we validated abnormal PAAT values in 54 children with PH. Methods and Results—: We conducted a prospective echocardiographic study in 756 healthy children (aged 1 day to 18 years) and in 54 children with PH. Possible associations of age, body length, body weight, body surface area, and heart rate on PAAT were investigated. The PAAT correlated positively with age ( r =0.848), body length ( r =0.871), body surface area ( r =0.856), and body weight ( r =0.825) and negatively with heart rate ( r =−0.906). PAAT increased with age (neonates: median: 81 ms, range: 53–104; 18th year of life: median: 151 ms, range: 107–187). Receiver operating characteristic analysis for detecting PH patients using age-specific z scores showed an excellent performance of PAAT ( P <0.001; area under the curve, 0.98; 95% confidence interval, 0.97–0.99) with a best cutoff score according to Youden index of –1.565 (sensitivity: 92%, specificity: 96%). PAAT values of PH patients negatively correlated (ρ=−0.497) with pulmonary vascular resistance. Conclusions—: The PAAT normal reference values and z scores we provideAbstract : Background—: Pulsed-wave Doppler determination of the pulmonary artery acceleration time (PAAT) as a surrogate for pulmonary artery pressure was found to be of clinical value for assessment of pulmonary hypertension (PH) with studies to date exclusively performed in adults. This study aims to provide representative, normal reference values for PAAT in children of all ages. Moreover, we validated abnormal PAAT values in 54 children with PH. Methods and Results—: We conducted a prospective echocardiographic study in 756 healthy children (aged 1 day to 18 years) and in 54 children with PH. Possible associations of age, body length, body weight, body surface area, and heart rate on PAAT were investigated. The PAAT correlated positively with age ( r =0.848), body length ( r =0.871), body surface area ( r =0.856), and body weight ( r =0.825) and negatively with heart rate ( r =−0.906). PAAT increased with age (neonates: median: 81 ms, range: 53–104; 18th year of life: median: 151 ms, range: 107–187). Receiver operating characteristic analysis for detecting PH patients using age-specific z scores showed an excellent performance of PAAT ( P <0.001; area under the curve, 0.98; 95% confidence interval, 0.97–0.99) with a best cutoff score according to Youden index of –1.565 (sensitivity: 92%, specificity: 96%). PAAT values of PH patients negatively correlated (ρ=−0.497) with pulmonary vascular resistance. Conclusions—: The PAAT normal reference values and z scores we provide here will be useful to identify children with a shortened PAAT. Abnormal PAAT values with scores <−2 were predictive of PH. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 10:Number 1(2017)
- Journal:
- Circulation
- Issue:
- Volume 10:Number 1(2017)
- Issue Display:
- Volume 10, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 10
- Issue:
- 1
- Issue Sort Value:
- 2017-0010-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-01
- Subjects:
- body surface area -- body weight -- child -- echocardiography -- heart rate
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.1075405 - Journal URLs:
- http://circimaging.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCIMAGING.116.005336 ↗
- Languages:
- English
- ISSNs:
- 1941-9651
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4461.xml