A theoretical comparison of tissue parameter extraction methods for dual energy computed tomography. Issue 8 (18th July 2014)
- Record Type:
- Journal Article
- Title:
- A theoretical comparison of tissue parameter extraction methods for dual energy computed tomography. Issue 8 (18th July 2014)
- Main Title:
- A theoretical comparison of tissue parameter extraction methods for dual energy computed tomography
- Authors:
- Tremblay, Jean‐Étienne
Bedwani, Stéphane
Bouchard, Hugo - Abstract:
- Abstract : Purpose: To evaluate the reliability of common sinogram‐based DECT reconstruction methods for radiotherapy tissue characterization and to evaluate the advantage of combining them with a stoichiometric calibration. Methods: The sinogram‐based DECT method defined by Alvarez and Macovski ["Energy‐selective reconstructions in x‐ray computerized tomography, " Phys. Med. Biol. 21, – (1976)] is adapted to the XCOM photon cross sections database and also generalized to a two‐material decomposition method. A theoretical framework is developed using a test phantom containing human tissue compositions for comparing the sinogram‐based methods and the calibration‐based method, being defined as the application of the stoichiometric calibration technique of Bourque et al. ["A stoichiometric calibration method for dual energy computed tomography, " Phys. Med. Biol. 59, 2059–2088 (2014)] on monoenergetic images being generated with a sinogram‐based method. Applying a bias correction to the sinogram‐based method, its performance in extracting human tissue parameters in the presence of noise as well as by altering the photon energy spectrum is compared to the calibration‐based method. Results: In the absence of noise and without spectrum alteration, the calibration‐based method is found to have no benefit on the sinogram‐based method. However, the calibration‐based method is shown to be potentially more reliable than bias‐corrected sinogram‐based methods in situations comparable toAbstract : Purpose: To evaluate the reliability of common sinogram‐based DECT reconstruction methods for radiotherapy tissue characterization and to evaluate the advantage of combining them with a stoichiometric calibration. Methods: The sinogram‐based DECT method defined by Alvarez and Macovski ["Energy‐selective reconstructions in x‐ray computerized tomography, " Phys. Med. Biol. 21, – (1976)] is adapted to the XCOM photon cross sections database and also generalized to a two‐material decomposition method. A theoretical framework is developed using a test phantom containing human tissue compositions for comparing the sinogram‐based methods and the calibration‐based method, being defined as the application of the stoichiometric calibration technique of Bourque et al. ["A stoichiometric calibration method for dual energy computed tomography, " Phys. Med. Biol. 59, 2059–2088 (2014)] on monoenergetic images being generated with a sinogram‐based method. Applying a bias correction to the sinogram‐based method, its performance in extracting human tissue parameters in the presence of noise as well as by altering the photon energy spectrum is compared to the calibration‐based method. Results: In the absence of noise and without spectrum alteration, the calibration‐based method is found to have no benefit on the sinogram‐based method. However, the calibration‐based method is shown to be potentially more reliable than bias‐corrected sinogram‐based methods in situations comparable to the clinical environment, where noise is present and the photon energy spectra can differ from what is used during image reconstruction. In determining electron density, the performance of all methods is comparable in the presence of noise only. Moreover, combined with heavy spectrum alteration, the mean errors on electron density are found higher in sinogram‐based methods in comparison with the calibration‐based method, with 1.2% versus 0.2%. In the presence of significant noise, bias‐corrected sinogram‐based methods yield mean errors on effective atomic number of about 2.5%, as compared to 0.5% for the calibration‐based method. When combined with heavy spectrum alteration, bias‐corrected sinogram‐based methods can lead to error of up to 4% on the effective atomic number versus 1.8% for the calibration‐based method. Conclusions: While sinogram‐based methods have the advantage of eliminating beam hardening effects, results of this study suggest improvements in the accuracy and reliability of extracting tissue parameters by applying the DECT stoichiometric calibration of Bourque et al. to monoenergetic images being generated with such DECT reconstruction methods. … (more)
- Is Part Of:
- Medical physics. Volume 41:Issue 8(2014)Part 1
- Journal:
- Medical physics
- Issue:
- Volume 41:Issue 8(2014)Part 1
- Issue Display:
- Volume 41, Issue 8, Part 1 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 8
- Part:
- 1
- Issue Sort Value:
- 2014-0041-0008-0001
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2014-07-18
- Subjects:
- Computed tomography -- Reconstruction -- Conformal radiation treatment
biological tissues -- computerised tomography -- electron density -- feature extraction -- image reconstruction -- medical image processing -- phantoms -- radiation therapy
computed tomography -- dual energy -- image reconstruction -- electron density -- effective atomic number -- stoichiometric calibration
Computerised tomographs -- Radiation therapy -- Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general
Computed tomography -- Calibration -- Tissues -- Photons -- Medical image noise -- Medical image reconstruction -- Image reconstruction -- X‐ray spectra -- Radiation therapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4886055 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4454.xml