Balloon-occluded transarterial chemoembolization using a 1.8-French tip Coaxial microballoon catheter for hepatocellular carcinoma: Technical and safety considerations. Issue 2 (April 2014)
- Record Type:
- Journal Article
- Title:
- Balloon-occluded transarterial chemoembolization using a 1.8-French tip Coaxial microballoon catheter for hepatocellular carcinoma: Technical and safety considerations. Issue 2 (April 2014)
- Main Title:
- Balloon-occluded transarterial chemoembolization using a 1.8-French tip Coaxial microballoon catheter for hepatocellular carcinoma: Technical and safety considerations
- Authors:
- Matsumoto, Tomohiro
Endo, Jun
Hashida, Kazunobu
Ichikawa, Hitoshi
Kojima, Seiichiro
Takashimizu, Shinji
Watanabe, Norihito
Yamagami, Takuji
Hasebe, Terumitsu - Abstract:
- Abstract: Objective : To evaluate the technical feasibility and safety considerations of balloon-occluded transarterial chemoembolization (B-TACE) using a newly developed 1.8-French (Fr) tip microballoon catheter for hepatocellular carcinoma (HCC).Material and methods : Between February 2013 and May 2013, 31 patients (20 males, 11 females; age range 56–85 years) underwent B-TACE using a 1.8-Fr tip microballoon catheter for unresectable HCC. The technical success rate, procedural complications, and adverse events of B-TACE were retrospectively investigated.Results : A total of 31 patients were subjected to 70 sessions of B-TACE using a 1.8-Fr tip microballoon catheter. The level of B-TACE was sub-subsegmental in 11, subsegmental in 35, segmental in 14, lobar in five, and right inferior phrenic artery in five sessions. The overall technical success rate was 99% (69 out of 70 sessions). As procedural complications, rupturing of the microballoon ( n = 3) and aneurysmal dilatation at the site of balloon occlusion ( n = 2) were encountered. There were no significant differences in any parameters between blood biochemical examination before and between two to four weeks after the procedure.Conclusion : A 1.8-Fr tip microballoon catheter enables selective catheterization in patients with HCC and B-TACE using the 1.8-Fr tip microballoon catheter is a safe procedure.
- Is Part Of:
- Minimally invasive therapy & allied technologies. Volume 24:Issue 2(2015)
- Journal:
- Minimally invasive therapy & allied technologies
- Issue:
- Volume 24:Issue 2(2015)
- Issue Display:
- Volume 24, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 24
- Issue:
- 2
- Issue Sort Value:
- 2015-0024-0002-0000
- Page Start:
- 94
- Page End:
- 100
- Publication Date:
- 2014-04
- Subjects:
- Interventional radiology -- catheter interventions -- minimally invasive procedures -- balloon-occluded transarterial chemoembolization -- hepatocellular carcinoma -- microballoon catheter
Endoscopy -- Periodicals
Interventional radiology -- Periodicals
Endoscopic surgery -- Periodicals
617.05 - Journal URLs:
- http://informahealthcare.com/loi/mit ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/13645706.2014.951657 ↗
- Languages:
- English
- ISSNs:
- 1364-5706
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5797.714000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4452.xml