A validated liquid chromatography mass spectrometry method for the quantification of tinoridine hydrochloride in rat plasma and its application to pharmacokinetic studies. Issue 5 (26th January 2015)
- Record Type:
- Journal Article
- Title:
- A validated liquid chromatography mass spectrometry method for the quantification of tinoridine hydrochloride in rat plasma and its application to pharmacokinetic studies. Issue 5 (26th January 2015)
- Main Title:
- A validated liquid chromatography mass spectrometry method for the quantification of tinoridine hydrochloride in rat plasma and its application to pharmacokinetic studies
- Authors:
- Kalariya, Pradipbhai D.
Patel, Prinesh N.
Swamy, Challa Veerabhadra
Srinivas, R.
Talluri, M. V. N. Kumar - Abstract:
- Abstract : A selective, sensitive and fast liquid chromatography coupled with mass spectrometry method (LC-MS) has been developed and validated for the quantification of tinoridine hydrochloride in rat plasma. Abstract : A selective, sensitive and fast liquid chromatography coupled with mass spectrometry method (LC-MS) has been developed and validated for the quantification of tinoridine hydrochloride in rat plasma using ketorolac tromethamine as an internal standard. Pre-treatment of the sample obtained from the plasma involved a simple and reliable protein precipitation method using methanol. A successful chromatographic separation was achieved on a Zorbax extended C18 column (50 mm × 2.1 mm, 1.8 μm) using acetonitrile and 0.1% formic acid as the mobile phase in gradient elution mode with a flow rate of 0.5 mL min −1 . Detection was performed with positive ion electrospray ionization mass spectrometry using target ions of [M + H] + at m / z 317 for tinoridine and m / z 256 for ketorolac in selective ion mode. The method was validated in the calibration range of 2–200 ng mL −1 . All the validation parameters were well within the limits. This method was further successfully applied in pharmacokinetic studies of the drug in rats.
- Is Part Of:
- Analytical methods. Volume 7:Issue 5(2015)
- Journal:
- Analytical methods
- Issue:
- Volume 7:Issue 5(2015)
- Issue Display:
- Volume 7, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 7
- Issue:
- 5
- Issue Sort Value:
- 2015-0007-0005-0000
- Page Start:
- 1965
- Page End:
- 1970
- Publication Date:
- 2015-01-26
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c4ay02898h ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4442.xml