Reduced ventilation–perfusion (V/Q) mismatch following endobronchial valve insertion demonstrated by Gallium‐68 V/Q photon emission tomography/computed tomography. Issue 5 (10th August 2017)
- Record Type:
- Journal Article
- Title:
- Reduced ventilation–perfusion (V/Q) mismatch following endobronchial valve insertion demonstrated by Gallium‐68 V/Q photon emission tomography/computed tomography. Issue 5 (10th August 2017)
- Main Title:
- Reduced ventilation–perfusion (V/Q) mismatch following endobronchial valve insertion demonstrated by Gallium‐68 V/Q photon emission tomography/computed tomography
- Authors:
- Leong, Paul
Le Roux, Pierre‐Yves
Callahan, Jason
Siva, Shankar
Hofman, Michael S
Steinfort, Daniel P - Abstract:
- Abstract : Endobronchial valves (EBVs) are increasingly deployed in the management of severe emphysema. Initial studies focussed on volume reduction as the mechanism, with subsequent improvement in forced expiratory volume in 1 s (FEV1 ). More recent studies have emphasized importance of perfusion on predicting outcomes, though findings have been inconsistent. Gallium‐68 ventilation–perfusion (V/Q) photon emission tomography (PET)/computed tomography (CT) is a novel imaging modality with advantages in spatial resolution, quantitation, and speed over conventional V/Q scintigraphy. We report a pilot case in which V/Q‐PET/CT demonstrated discordant findings compared with quantitative CT analysis, and directed left lower lobe EBV placement. The patient experienced a significant improvement in 6‐min walk distance (6MWD) without change in spirometry. Post‐EBV V/Q‐PET/CT demonstrated a marked decrease in unmatched (detrimental) V/Q areas and improvement in overall V/Q matching on post‐EBV V/Q‐PET/CT. These preliminary novel findings suggest that EBVs improve V/Q matching and may explain the observed functional improvements. Abstract : Endobronchial valves (EBVs) are increasingly used in severe emphysema. Using Gallium‐68 ventilation–perfusion (V/Q) photon emission tomography (PET)/computed tomography (CT), we report a pilot case in which PET/CT findings were discordant to standard quantitative CT analysis. We deployed valves in a lobe where benefit was not predicted with standardAbstract : Endobronchial valves (EBVs) are increasingly deployed in the management of severe emphysema. Initial studies focussed on volume reduction as the mechanism, with subsequent improvement in forced expiratory volume in 1 s (FEV1 ). More recent studies have emphasized importance of perfusion on predicting outcomes, though findings have been inconsistent. Gallium‐68 ventilation–perfusion (V/Q) photon emission tomography (PET)/computed tomography (CT) is a novel imaging modality with advantages in spatial resolution, quantitation, and speed over conventional V/Q scintigraphy. We report a pilot case in which V/Q‐PET/CT demonstrated discordant findings compared with quantitative CT analysis, and directed left lower lobe EBV placement. The patient experienced a significant improvement in 6‐min walk distance (6MWD) without change in spirometry. Post‐EBV V/Q‐PET/CT demonstrated a marked decrease in unmatched (detrimental) V/Q areas and improvement in overall V/Q matching on post‐EBV V/Q‐PET/CT. These preliminary novel findings suggest that EBVs improve V/Q matching and may explain the observed functional improvements. Abstract : Endobronchial valves (EBVs) are increasingly used in severe emphysema. Using Gallium‐68 ventilation–perfusion (V/Q) photon emission tomography (PET)/computed tomography (CT), we report a pilot case in which PET/CT findings were discordant to standard quantitative CT analysis. We deployed valves in a lobe where benefit was not predicted with standard quantitative CT, and found significant clinical improvement and improved V/Q matching on repeat imaging. … (more)
- Is Part Of:
- Respirology case reports. Volume 5:Issue 5(2017)
- Journal:
- Respirology case reports
- Issue:
- Volume 5:Issue 5(2017)
- Issue Display:
- Volume 5, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 5
- Issue:
- 5
- Issue Sort Value:
- 2017-0005-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-08-10
- Subjects:
- Bronchial valve implants -- bronchoscopy -- positron emission tomography -- ventilation
Respiratory organs -- Diseases -- Periodicals
616.2005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2051-3380/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/rcr2.253 ↗
- Languages:
- English
- ISSNs:
- 2051-3380
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4443.xml