3D Multiecho Dixon for the Evaluation of Hepatic Iron and Fat in a Clinical Setting. Issue 3 (22nd February 2017)
- Record Type:
- Journal Article
- Title:
- 3D Multiecho Dixon for the Evaluation of Hepatic Iron and Fat in a Clinical Setting. Issue 3 (22nd February 2017)
- Main Title:
- 3D Multiecho Dixon for the Evaluation of Hepatic Iron and Fat in a Clinical Setting
- Authors:
- Henninger, Benjamin
Zoller, Heinz
Kannengiesser, Stephan
Zhong, Xiaodong
Jaschke, Werner
Kremser, Christian - Abstract:
- Abstract : Purpose: To prospectively evaluate a new 3D‐multiecho‐Dixon (3D‐ME‐Dixon) sequence for the quantification of hepatic iron and fat in a clinical setting. Materials and Methods: In all, 120 patients underwent 1.5T magnetic resonance imaging of the liver between December 2013 and June 2015 including the following three sequences: 3D‐ME‐Dixon with inline calculation of R2* and proton‐density fat‐fraction (PDFF) maps, single‐voxel‐spectroscopy (SVS), 2D multigradient‐echo sequence (2D‐ME‐GRE). SVS and 2D‐ME‐GRE were used as reference for PDFF and R2*, respectively. R2*‐ and PDFF‐values from 3D‐ME‐Dixon were compared with those of the reference. Linear regression analysis, Bland–Altman plots, and agreement parameters were calculated. Results: In total, 103 patients were finally included (87 men and 16 women; mean age, 50.51 years); 17/120 were excluded due to fat/water‐swaps or R2*‐values exceeding the constraint of 400 1/s for 3D‐ME‐Dixon. A strong correlation ( r = 0.992, P < 0.001) between R2* of 3D‐ME‐Dixon and the reference 2D‐ME‐GRE was found. Bland–Altman analysis revealed systematically lower values for 3D‐ME‐Dixon (16.499%). Using an adapted threshold of 57 1/s, 3D‐ME‐Dixon obtained a positive/negative percentage agreement (PPA/NPA) of 84.4%/91.4% for detecting hepatic iron overload. For hepatic fat the correlation between 3D‐ME‐Dixon and the reference SVS was strong ( r = 0.957, P < 0.001); PPA/NPA was 88.3%/91.4%. Conclusion: The 3D‐ME‐Dixon sequence is aAbstract : Purpose: To prospectively evaluate a new 3D‐multiecho‐Dixon (3D‐ME‐Dixon) sequence for the quantification of hepatic iron and fat in a clinical setting. Materials and Methods: In all, 120 patients underwent 1.5T magnetic resonance imaging of the liver between December 2013 and June 2015 including the following three sequences: 3D‐ME‐Dixon with inline calculation of R2* and proton‐density fat‐fraction (PDFF) maps, single‐voxel‐spectroscopy (SVS), 2D multigradient‐echo sequence (2D‐ME‐GRE). SVS and 2D‐ME‐GRE were used as reference for PDFF and R2*, respectively. R2*‐ and PDFF‐values from 3D‐ME‐Dixon were compared with those of the reference. Linear regression analysis, Bland–Altman plots, and agreement parameters were calculated. Results: In total, 103 patients were finally included (87 men and 16 women; mean age, 50.51 years); 17/120 were excluded due to fat/water‐swaps or R2*‐values exceeding the constraint of 400 1/s for 3D‐ME‐Dixon. A strong correlation ( r = 0.992, P < 0.001) between R2* of 3D‐ME‐Dixon and the reference 2D‐ME‐GRE was found. Bland–Altman analysis revealed systematically lower values for 3D‐ME‐Dixon (16.499%). Using an adapted threshold of 57 1/s, 3D‐ME‐Dixon obtained a positive/negative percentage agreement (PPA/NPA) of 84.4%/91.4% for detecting hepatic iron overload. For hepatic fat the correlation between 3D‐ME‐Dixon and the reference SVS was strong ( r = 0.957, P < 0.001); PPA/NPA was 88.3%/91.4%. Conclusion: The 3D‐ME‐Dixon sequence is a valuable tool for the evaluation of hepatic iron and fat in a clinical setting. Fat/water‐swaps remain a drawback requiring improvements to the implementation and making it necessary to have proven conventional sequences at hand in case of an eventual occurrence. Level of Evidence : 1. Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:793–800 … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 46:Issue 3(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 46:Issue 3(2017)
- Issue Display:
- Volume 46, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 3
- Issue Sort Value:
- 2017-0046-0003-0000
- Page Start:
- 793
- Page End:
- 800
- Publication Date:
- 2017-02-22
- Subjects:
- MRI -- liver -- iron -- fat -- Dixon -- relaxometry
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25630 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4422.xml