Airborne-particle abrasion with niobium phosphate bioactive glass on caries-affected dentin: effect on the microtensile bond strength. Issue 22 (17th November 2017)
- Record Type:
- Journal Article
- Title:
- Airborne-particle abrasion with niobium phosphate bioactive glass on caries-affected dentin: effect on the microtensile bond strength. Issue 22 (17th November 2017)
- Main Title:
- Airborne-particle abrasion with niobium phosphate bioactive glass on caries-affected dentin: effect on the microtensile bond strength
- Authors:
- Leal, Adriana
Carvalho, Ceci
Maia-Filho, Etevaldo
Monteiro-Neto, Valério
Carmo, Monique
Maciel, Adeilton
Bauer, Jose - Abstract:
- Abstract: This study evaluated the effect of airborne-particle abrasion with niobium phosphate bioglass (NbG) microparticles on the bond strength (μTBS) and longevity of an adhesive system to different dentin substrates. In this study, 18 Caries-free molars were used, of which 12 were microbiologically processed for caries induction. The dentin surfaces were evaluated in three groups: (1) Control – Healthy Dentin; (2) Partial removal of carious tissue; (3) complete removal of carious tissue. Half the teeth in each group were submitted to airborne-particle abrasion with NbG microparticles (15 s/1 cm/5 bar). After this, the adhesive Clearfil S 3 was applied and composite buildups were constructed incrementally; and specimens were longitudinally sectioned to obtain bonded sticks (1.0 mm 2 ) to be tested in tension (0.5 mm/min) immediately or after 6 months of storage in water. The fracture patterns were evaluated by stereomicroscope (40×) and then by scanning electron microscopy. The data were analyzed by the Kruskal-Wallis ( post hoc Dunn) and Mann-Whitney tests ( α = 0.05). Healthy dentin showed the highest bond strength (μTBS). Airborne-particle abrasion with NbG increased the μTBS values in the Group with complete caries removal. The bond strength values in the 24-h period were higher than those at 6 months. In the majority of the specimens the fracture mode was adhesive/mixed. The authors concluded that airborne-particle abrasion on dentin with NbG particles increased theAbstract: This study evaluated the effect of airborne-particle abrasion with niobium phosphate bioglass (NbG) microparticles on the bond strength (μTBS) and longevity of an adhesive system to different dentin substrates. In this study, 18 Caries-free molars were used, of which 12 were microbiologically processed for caries induction. The dentin surfaces were evaluated in three groups: (1) Control – Healthy Dentin; (2) Partial removal of carious tissue; (3) complete removal of carious tissue. Half the teeth in each group were submitted to airborne-particle abrasion with NbG microparticles (15 s/1 cm/5 bar). After this, the adhesive Clearfil S 3 was applied and composite buildups were constructed incrementally; and specimens were longitudinally sectioned to obtain bonded sticks (1.0 mm 2 ) to be tested in tension (0.5 mm/min) immediately or after 6 months of storage in water. The fracture patterns were evaluated by stereomicroscope (40×) and then by scanning electron microscopy. The data were analyzed by the Kruskal-Wallis ( post hoc Dunn) and Mann-Whitney tests ( α = 0.05). Healthy dentin showed the highest bond strength (μTBS). Airborne-particle abrasion with NbG increased the μTBS values in the Group with complete caries removal. The bond strength values in the 24-h period were higher than those at 6 months. In the majority of the specimens the fracture mode was adhesive/mixed. The authors concluded that airborne-particle abrasion on dentin with NbG particles increased the μTBS in the group in which carious dentin was completely removed. … (more)
- Is Part Of:
- Journal of adhesion science and technology. Volume 31:Issue 22(2017)
- Journal:
- Journal of adhesion science and technology
- Issue:
- Volume 31:Issue 22(2017)
- Issue Display:
- Volume 31, Issue 22 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 22
- Issue Sort Value:
- 2017-0031-0022-0000
- Page Start:
- 2410
- Page End:
- 2423
- Publication Date:
- 2017-11-17
- Subjects:
- Minimally invasive dentistry -- bioactive glasses -- dentin reparation -- microtensile bond strength -- dental caries -- dentin -- adhesive systems
Adhesion -- Periodicals
Adhesives -- Periodicals
668.3 - Journal URLs:
- http://www.tandfonline.com/toc/tast20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/01694243.2017.1303865 ↗
- Languages:
- English
- ISSNs:
- 0169-4243
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4918.936000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2952.xml