Long-term vagal stimulation for heart failure: Eighteen month results from the NEural Cardiac TherApy foR Heart Failure (NECTAR-HF) trial. (1st October 2017)
- Record Type:
- Journal Article
- Title:
- Long-term vagal stimulation for heart failure: Eighteen month results from the NEural Cardiac TherApy foR Heart Failure (NECTAR-HF) trial. (1st October 2017)
- Main Title:
- Long-term vagal stimulation for heart failure: Eighteen month results from the NEural Cardiac TherApy foR Heart Failure (NECTAR-HF) trial
- Authors:
- De Ferrari, Gaetano M.
Stolen, Craig
Tuinenburg, Anton E.
Wright, D. Jay
Brugada, Josep
Butter, Christian
Klein, Helmut
Neuzil, Petr
Botman, Cornelis
Castel, Maria Angeles
D'Onofrio, Antonio
de Borst, Gert J.
Solomon, Scott
Stein, Kenneth M.
Schubert, Bernd
Stalsberg, Kevin
Wold, Nicholas
Ruble, Stephen
Zannad, Faiez - Abstract:
- Abstract: Background: The NECTAR-HF study evaluated safety and feasibility of vagal nerve stimulation (VNS) for the treatment of heart failure patients. The first six-month randomized phase of the study did not show improvement in left ventricular remodelling in response to VNS. This study reports the 18-month results and provides novel findings aiming to understand the lack of efficacy of VNS, including a new technique assessing the effects of VNS. Methods: Ninety-six patients were randomized 2:1 to active or inactive VNS for 6 months, thereafter VNS was activated for all patients. The primary safety endpoint was 18-month all-cause mortality. Results: Ninety-one patients continued in the long-term evaluation with active VNS. The on-therapy survival estimate at 18 months was 95% with a 95% one-sided lower confidence limit of 91%, (better than the predefined criterion). Left ventricular systolic volume decreased in the crossover group (VNS OFF → ON; 144 ± 37 to 139 ± 40, p < 0.05) after VNS activation; LVESD (5.02 ± 0.77 to 4.96 ± 0.82, p > 0.05) and LVEF (33.2 ± 4.9 to 33.3 ± 6.5, p > 0.05) did not change. A new technique to detect subtle heart rate changes during Holter recordings, i.e. "heat maps", revealed that VNS evoked heart rate response in only 13/106 studies (12%) at 6 and 12 months with active VNS. Conclusions: Although a favourable long-term safety profile was found, improvements in the efficacy endpoints were not seen with VNS. A new technique for detecting acuteAbstract: Background: The NECTAR-HF study evaluated safety and feasibility of vagal nerve stimulation (VNS) for the treatment of heart failure patients. The first six-month randomized phase of the study did not show improvement in left ventricular remodelling in response to VNS. This study reports the 18-month results and provides novel findings aiming to understand the lack of efficacy of VNS, including a new technique assessing the effects of VNS. Methods: Ninety-six patients were randomized 2:1 to active or inactive VNS for 6 months, thereafter VNS was activated for all patients. The primary safety endpoint was 18-month all-cause mortality. Results: Ninety-one patients continued in the long-term evaluation with active VNS. The on-therapy survival estimate at 18 months was 95% with a 95% one-sided lower confidence limit of 91%, (better than the predefined criterion). Left ventricular systolic volume decreased in the crossover group (VNS OFF → ON; 144 ± 37 to 139 ± 40, p < 0.05) after VNS activation; LVESD (5.02 ± 0.77 to 4.96 ± 0.82, p > 0.05) and LVEF (33.2 ± 4.9 to 33.3 ± 6.5, p > 0.05) did not change. A new technique to detect subtle heart rate changes during Holter recordings, i.e. "heat maps", revealed that VNS evoked heart rate response in only 13/106 studies (12%) at 6 and 12 months with active VNS. Conclusions: Although a favourable long-term safety profile was found, improvements in the efficacy endpoints were not seen with VNS. A new technique for detecting acute heart rate responses to VNS suggests that the recruitment of nerve fibres responsible for heart rate changes were substantially lower in NECTAR-HF than in pre-clinical models. … (more)
- Is Part Of:
- International journal of cardiology. Volume 244(2017)
- Journal:
- International journal of cardiology
- Issue:
- Volume 244(2017)
- Issue Display:
- Volume 244, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 244
- Issue:
- 2017
- Issue Sort Value:
- 2017-0244-2017-0000
- Page Start:
- 229
- Page End:
- 234
- Publication Date:
- 2017-10-01
- Subjects:
- Autonomic modulation -- Vagal nerve stimulation -- Heart failure -- Parasympathetic nervous system -- Vagus nerve -- Neural therapy
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2017.06.036 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2950.xml