Computational fluid dynamics based study for analyzing heat transfer and friction factor in semi-circular rib-roughened equilateral triangular duct. Issue 4 (3rd April 2017)
- Record Type:
- Journal Article
- Title:
- Computational fluid dynamics based study for analyzing heat transfer and friction factor in semi-circular rib-roughened equilateral triangular duct. Issue 4 (3rd April 2017)
- Main Title:
- Computational fluid dynamics based study for analyzing heat transfer and friction factor in semi-circular rib-roughened equilateral triangular duct
- Authors:
- Kumar, Rajneesh
Kumar, Anoop
, Varun - Abstract:
- Abstract : Purpose: The purpose of this computational fluid dynamics (CFD)-based study on semicircular rib-roughened equilateral triangular duct is to investigate heat transfer, friction factor and thermohydraulic performance parameter. The analysis is carried out by simulating problem in ANSYS (Fluent). The Reynolds number in the study varies from 4, 000 to 24, 000. Nusselt number is calculated for different Reynolds number using various turbulent models available in ANSYS (Fluent) for a smooth duct and compared the results with the Dittus–Boelter correlation. Design/methodology/approach: The analysis has been done by solving basic fluid governing equations (continuity, momentum and energy) by using finite volume method (FVM). The semicircular ribs were fabricated on the absorber plate. The constant amount of heat flux is applied on the absorber plate, whereas other two walls are made adiabatic. The semi-implicit method for pressure linked equations (SIMPLE) algorithm is used with pressure–velocity-coupled disretization to estimate the results. The selection of turbulent model has been done on the basis of Nusselt number prediction in the smooth duct. Findings: The renormalization-group k − ε model predicts the Nusselt number more accurately as compared to standard k − ε model, standard k − ω model, shear stress transport (SST) k − ω and realizable k − ε model in the Reynolds number ranges from 4, 000 to 24, 000 with a ± 5.5% deviation from Dittus–Boelter equation forAbstract : Purpose: The purpose of this computational fluid dynamics (CFD)-based study on semicircular rib-roughened equilateral triangular duct is to investigate heat transfer, friction factor and thermohydraulic performance parameter. The analysis is carried out by simulating problem in ANSYS (Fluent). The Reynolds number in the study varies from 4, 000 to 24, 000. Nusselt number is calculated for different Reynolds number using various turbulent models available in ANSYS (Fluent) for a smooth duct and compared the results with the Dittus–Boelter correlation. Design/methodology/approach: The analysis has been done by solving basic fluid governing equations (continuity, momentum and energy) by using finite volume method (FVM). The semicircular ribs were fabricated on the absorber plate. The constant amount of heat flux is applied on the absorber plate, whereas other two walls are made adiabatic. The semi-implicit method for pressure linked equations (SIMPLE) algorithm is used with pressure–velocity-coupled disretization to estimate the results. The selection of turbulent model has been done on the basis of Nusselt number prediction in the smooth duct. Findings: The renormalization-group k − ε model predicts the Nusselt number more accurately as compared to standard k − ε model, standard k − ω model, shear stress transport (SST) k − ω and realizable k − ε model in the Reynolds number ranges from 4, 000 to 24, 000 with a ± 5.5% deviation from Dittus–Boelter equation for smooth duct. The maximum thermo-hydraulic performance is observed of the order of 1.7 for arrangement which has a relative roughness height of 0.067 and relative roughness pitch of 7.5 at higher Reynolds Number of 24, 000. Originality/value: Although, many experimental studies are available in the area of rib-roughened ducts, the present study is based on CFD analysis of semicircular rib-roughened equilateral triangular duct and the results are predicted in terms of Nusselt number, friction factor and thermohydraulic performance parameter. Moreover, the predicted result of Nusselt number and friction factor is validated by comparing with Dittus–Boelter correlation and modified Blasius equation, respectively. This advantage made Fluent a powerful tool for analyzing the internal fluid flow through roughened ducts. … (more)
- Is Part Of:
- International journal of numerical methods for heat & fluid flow. Volume 27:Issue 4(2017)
- Journal:
- International journal of numerical methods for heat & fluid flow
- Issue:
- Volume 27:Issue 4(2017)
- Issue Display:
- Volume 27, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 27
- Issue:
- 4
- Issue Sort Value:
- 2017-0027-0004-0000
- Page Start:
- 941
- Page End:
- 957
- Publication Date:
- 2017-04-03
- Subjects:
- Forced convective heat transfer and friction factor -- Thermo-hydraulic performance -- Turbulent models
Heat -- Transmission -- Mathematics -- Periodicals
Fluid dynamics -- Mathematics -- Periodicals
536.2 - Journal URLs:
- http://info.emeraldinsight.com/products/journals/journals.htm?id=hff ↗
http://www.emeraldinsight.com/ ↗ - DOI:
- 10.1108/HFF-10-2015-0438 ↗
- Languages:
- English
- ISSNs:
- 0961-5539
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.406100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2935.xml