Evaluation of osseous‐associated cervical spondylomyelopathy in dogs using kinematic magnetic resonance imaging. Issue 4 (12th April 2017)
- Record Type:
- Journal Article
- Title:
- Evaluation of osseous‐associated cervical spondylomyelopathy in dogs using kinematic magnetic resonance imaging. Issue 4 (12th April 2017)
- Main Title:
- Evaluation of osseous‐associated cervical spondylomyelopathy in dogs using kinematic magnetic resonance imaging
- Authors:
- Provencher, Michele
Habing, Amy
Moore, Sarah A.
Cook, Laurie
Phillips, Gary
da Costa, Ronaldo C. - Abstract:
- Abstract: Osseous‐associated cervical spondylomyelopathy in dogs is characterized by both static and dynamic spinal cord compression; however, standard MRI methods only assess static compression. In humans with cervical spondylotic myelopathy, kinematic MRI is commonly used to diagnose dynamic spinal cord compressions. The purpose of this prospective, analytical study was to evaluate kinematic MRI as a method for characterizing the dynamic component of osseous‐associated cervical spondylomyelopathy in dogs. We hypothesized that kinematic MRI would allow visualization of spinal cord compressions that were not identified with standard imaging. Twelve client‐owned dogs with osseous‐associated cervical spondylomyelopathy were enrolled. After standard MRI confirmed a diagnosis of osseous‐associated cervical spondylomyelopathy, a positioning device was used to perform additional MRI sequences with the cervical vertebral column flexed and extended. Morphologic and morphometric (spinal cord height, intervertebral disc width, spinal cord width, vertebral canal height, and spinal cord area) assessments were recorded for images acquired with neutral, flexion, and extension imaging. A total of 25 compressions were seen with neutral positioning, while extension identified 32 compressions. There was a significant association between extension positioning and presence of a compressive lesion at C4‐C5 ( p = 0.02). Extension was also associated with a change in the most severe site ofAbstract: Osseous‐associated cervical spondylomyelopathy in dogs is characterized by both static and dynamic spinal cord compression; however, standard MRI methods only assess static compression. In humans with cervical spondylotic myelopathy, kinematic MRI is commonly used to diagnose dynamic spinal cord compressions. The purpose of this prospective, analytical study was to evaluate kinematic MRI as a method for characterizing the dynamic component of osseous‐associated cervical spondylomyelopathy in dogs. We hypothesized that kinematic MRI would allow visualization of spinal cord compressions that were not identified with standard imaging. Twelve client‐owned dogs with osseous‐associated cervical spondylomyelopathy were enrolled. After standard MRI confirmed a diagnosis of osseous‐associated cervical spondylomyelopathy, a positioning device was used to perform additional MRI sequences with the cervical vertebral column flexed and extended. Morphologic and morphometric (spinal cord height, intervertebral disc width, spinal cord width, vertebral canal height, and spinal cord area) assessments were recorded for images acquired with neutral, flexion, and extension imaging. A total of 25 compressions were seen with neutral positioning, while extension identified 32 compressions. There was a significant association between extension positioning and presence of a compressive lesion at C4‐C5 ( p = 0.02). Extension was also associated with a change in the most severe site of compression in four out of 12 (33%) dogs. None of the patients deteriorated neurologically after kinematic imaging. We concluded that kinematic MRI is a feasible method for evaluating dogs with osseous‐associated cervical spondylomyelopathy, and can reveal new compressions not seen with neutral positioning. … (more)
- Is Part Of:
- Veterinary radiology & ultrasound. Volume 58:Issue 4(2017)
- Journal:
- Veterinary radiology & ultrasound
- Issue:
- Volume 58:Issue 4(2017)
- Issue Display:
- Volume 58, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 58
- Issue:
- 4
- Issue Sort Value:
- 2017-0058-0004-0000
- Page Start:
- 411
- Page End:
- 421
- Publication Date:
- 2017-04-12
- Subjects:
- CSM -- dynamic -- extension -- flexion -- MRI -- wobbler
Veterinary radiology -- Periodicals
Radiologie vétérinaire -- Périodiques
Échographie vétérinaire -- Périodiques
Radiography -- Periodicals
Ultrasonography -- Periodicals
Diagnosis -- Periodicals
Veterinary Medicine -- Periodicals
Societies, Medical -- Periodicals
636.089607 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1740-8261 ↗
http://www.blackwell-synergy.com/loi/vru ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1058-8183;screen=info;ECOIP ↗
http://www.blackwell-synergy.com/loi/vru ↗ - DOI:
- 10.1111/vru.12495 ↗
- Languages:
- English
- ISSNs:
- 1058-8183
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9229.281000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2928.xml