Clinical outcome associated with the use of different inhalation method with and without humidification in asthmatic mechanically ventilated patients. (August 2017)
- Record Type:
- Journal Article
- Title:
- Clinical outcome associated with the use of different inhalation method with and without humidification in asthmatic mechanically ventilated patients. (August 2017)
- Main Title:
- Clinical outcome associated with the use of different inhalation method with and without humidification in asthmatic mechanically ventilated patients
- Authors:
- Moustafa, Islam O.F.
ElHansy, Muhammad H.E.
Al Hallag, Moataz
Fink, James B.
Dailey, Patricia
Rabea, Hoda
Abdelrahim, Mohamed E.A. - Abstract:
- Abstract: Background: Inhaled-medication delivered during mechanical-ventilation is affected by type of aerosol-generator and humidity-condition. Despite many in-vitro studies related to aerosol-delivery to mechanically-ventilated patients, little has been reported on clinical effects of these variables. The aim of this study was to determine effect of humidification and type of aerosol-generator on clinical status of mechanically ventilated asthmatics. Method: 72 (36 females) asthmatic subjects receiving invasive mechanical ventilation were enrolled and assigned randomly to 6 treatment groups of 12 (6 females) subjects each received, as possible, all inhaled medication using their assigned aerosol generator and humidity condition during delivery. Aerosol-generators were placed immediately after humidifier within inspiratory limb of mechanical ventilation circuit. First group used vibrating-mesh-nebulizer (Aerogen Solo; VMN) with humidification; Second used VMN without humidification; Third used metered-dose-inhaler with AeroChamber Vent (MDI-AV) with humidification; Forth used MDI-AV without humidification; Fifth used Oxycare jet-nebulizer (JN) with humidification; Sixth used JN without humidification. Measured parameters included clinical-parameters reflected patient response (CP) and endpoint parameters e.g. length-of-stay in the intensive-care-unit (ICU-days) and mechanical-ventilation days (MV-days). Results: There was no significant difference between studied subjectsAbstract: Background: Inhaled-medication delivered during mechanical-ventilation is affected by type of aerosol-generator and humidity-condition. Despite many in-vitro studies related to aerosol-delivery to mechanically-ventilated patients, little has been reported on clinical effects of these variables. The aim of this study was to determine effect of humidification and type of aerosol-generator on clinical status of mechanically ventilated asthmatics. Method: 72 (36 females) asthmatic subjects receiving invasive mechanical ventilation were enrolled and assigned randomly to 6 treatment groups of 12 (6 females) subjects each received, as possible, all inhaled medication using their assigned aerosol generator and humidity condition during delivery. Aerosol-generators were placed immediately after humidifier within inspiratory limb of mechanical ventilation circuit. First group used vibrating-mesh-nebulizer (Aerogen Solo; VMN) with humidification; Second used VMN without humidification; Third used metered-dose-inhaler with AeroChamber Vent (MDI-AV) with humidification; Forth used MDI-AV without humidification; Fifth used Oxycare jet-nebulizer (JN) with humidification; Sixth used JN without humidification. Measured parameters included clinical-parameters reflected patient response (CP) and endpoint parameters e.g. length-of-stay in the intensive-care-unit (ICU-days) and mechanical-ventilation days (MV-days). Results: There was no significant difference between studied subjects in the 6 groups in baseline of CP. VMN resulted in trend to shorter ICU-days (∼1.42days) compared to MDI-AV (p = 0.39) and relatively but not significantly shorter ICU-days (∼0.75days) compared JN. Aerosol-delivery with or without humidification did not have any significant effect on any of parameters studied with very light insignificant tendency of delivery at humid condition to decrease MV-days and ICU-days. No significant effect was found of changing humidity during aerosol-delivery to ventilated-patient. Conclusions: VMN to deliver aerosol in ventilated patient resulted in trend to decreased ICU-days compared to JN and MDI-AV. Aerosol-delivery with or without humidification did not have any significant effect on any of parameters studied. However, we recommend increasing the number of patients studied to corroborate this finding. … (more)
- Is Part Of:
- Pulmonary pharmacology & therapeutics. Volume 45(2017:Aug.)
- Journal:
- Pulmonary pharmacology & therapeutics
- Issue:
- Volume 45(2017:Aug.)
- Issue Display:
- Volume 45 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue Sort Value:
- 2017-0045-0000-0000
- Page Start:
- 40
- Page End:
- 46
- Publication Date:
- 2017-08
- Subjects:
- Vibrating mesh nebulisers -- MDI -- Spacer -- Non-invasive ventilation -- Urinary salbutamol -- Humidification
Respiratory organs -- Diseases -- Chemotherapy -- Periodicals
615.7205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10945539 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/pulmonary-pharmacology-and-therapeutics/ ↗ - DOI:
- 10.1016/j.pupt.2017.04.007 ↗
- Languages:
- English
- ISSNs:
- 1094-5539
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7156.978500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2922.xml