Measuring modified glass bulb sprinkler thermal response in plunge and compartment fire experiments. (July 2017)
- Record Type:
- Journal Article
- Title:
- Measuring modified glass bulb sprinkler thermal response in plunge and compartment fire experiments. (July 2017)
- Main Title:
- Measuring modified glass bulb sprinkler thermal response in plunge and compartment fire experiments
- Authors:
- Frank, Kevin
Spearpoint, Michael
Baker, Greg
Wade, Colleen
Collier, Peter
Fleischmann, Charles - Abstract:
- Abstract: Automatic fire sprinklers use a heat sensitive element such as a glass bulb or fusible link to respond to the heat from a fire. The response of commercial fire sprinkler glass bulbs has been extensively characterised in convection-dominated dry gas flows but in real fires there may be more factors that influence the heat transfer to the bulbs such as radiation from the fire or cooling from adjacent sprinkler sprays. The time of activation is the only indication of the thermal response of typical commercial fire sprinklers using glass bulbs to a fire, but direct temperature measurement using a modified proxy may provide a better understanding of how sprinklers respond in a complex environment. Modified glass bulbs have been created that allow a thermocouple to be inserted in the bulb for direct temperature measurement. In this paper, the thermal response of sprinklers with these modified bulbs has been observed in hot-air wind tunnel plunge experiments and full scale room fire experiments. At the time of activation the measured temperature of the modified sprinklers was found to be higher than the nominal activation temperature specification for the unmodified sprinklers. For the compartment fires, a thermal response model generally predicted longer sprinkler activation times based on ceiling jet temperature and velocity measurements than was observed experimentally.
- Is Part Of:
- Fire safety journal. Volume 91(2017:Jul.)
- Journal:
- Fire safety journal
- Issue:
- Volume 91(2017:Jul.)
- Issue Display:
- Volume 91 (2017)
- Year:
- 2017
- Volume:
- 91
- Issue Sort Value:
- 2017-0091-0000-0000
- Page Start:
- 662
- Page End:
- 670
- Publication Date:
- 2017-07
- Subjects:
- Sprinklers -- Detection -- Heat transfer -- Compartment fires
Fire prevention -- Periodicals
Incendies -- Prévention -- Recherche -- Périodiques
Fire prevention -- Research
Periodicals
628.92205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03797112 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.firesaf.2017.03.017 ↗
- Languages:
- English
- ISSNs:
- 0379-7112
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3933.285000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2926.xml