Within‐ and between‐session reproducibility of GABA measurements with MR spectroscopy. Issue 2 (15th February 2017)
- Record Type:
- Journal Article
- Title:
- Within‐ and between‐session reproducibility of GABA measurements with MR spectroscopy. Issue 2 (15th February 2017)
- Main Title:
- Within‐ and between‐session reproducibility of GABA measurements with MR spectroscopy
- Authors:
- Brix, Maiken K.
Ersland, Lars
Hugdahl, Kenneth
Dwyer, Gerard E.
Grüner, Renate
Noeske, Ralph
Beyer, Mona K.
Craven, Alexander R. - Abstract:
- Abstract : Purpose: The reproducibility of the MEGA‐PRESS (MEshcher‐GArwood Point RESolved Spectroscopy) MR spectroscopy sequence for the measurement of gamma‐ aminobutyric acid (GABA) is addressed, focusing on optimizing the number of repetitions at two voxel locations in the human brain and associated possibilities in analysis tools. Materials and Methods: Two 20‐min MEGA‐PRESS acquisitions were run (echo time = 68 ms, repetition time = 1800 ms, repetitions = 328): one from a 21 mL volume in the anterior cingulate cortex (ACC) and one from a 22 mL volume in the left Broca's area in 21 healthy male volunteers (age 32 years ± 6[SD]). Subjects were scanned twice with identical protocols, 1 week apart. Data were acquired on a 3 Tesla GE Discovery 750 scanner using a 32‐channel head coil. Spectroscopy data were partitioned into shorter epochs, numerically equivalent to scans of progressively increasing duration, and compared both within and between sessions. Three different analysis schemes were applied: (1) Vendor prototype preprocessor, with quantification by LCModel. (2) Pure Gannet pipeline. (3) Preprocessing with Gannet, and quantification with LCModel. The coefficient of variation (CV) were calculated as a measure of reproducibility. Results: Increasing the number of repetitions showed improvements for within‐ and between‐session reproducibility up to around 218 repetitions. (CV ranging from 4 to 14%). Gannet combined with LCModel approach proved the best method.Abstract : Purpose: The reproducibility of the MEGA‐PRESS (MEshcher‐GArwood Point RESolved Spectroscopy) MR spectroscopy sequence for the measurement of gamma‐ aminobutyric acid (GABA) is addressed, focusing on optimizing the number of repetitions at two voxel locations in the human brain and associated possibilities in analysis tools. Materials and Methods: Two 20‐min MEGA‐PRESS acquisitions were run (echo time = 68 ms, repetition time = 1800 ms, repetitions = 328): one from a 21 mL volume in the anterior cingulate cortex (ACC) and one from a 22 mL volume in the left Broca's area in 21 healthy male volunteers (age 32 years ± 6[SD]). Subjects were scanned twice with identical protocols, 1 week apart. Data were acquired on a 3 Tesla GE Discovery 750 scanner using a 32‐channel head coil. Spectroscopy data were partitioned into shorter epochs, numerically equivalent to scans of progressively increasing duration, and compared both within and between sessions. Three different analysis schemes were applied: (1) Vendor prototype preprocessor, with quantification by LCModel. (2) Pure Gannet pipeline. (3) Preprocessing with Gannet, and quantification with LCModel. The coefficient of variation (CV) were calculated as a measure of reproducibility. Results: Increasing the number of repetitions showed improvements for within‐ and between‐session reproducibility up to around 218 repetitions. (CV ranging from 4 to 14%). Gannet combined with LCModel approach proved the best method. (CV = 4–5%). Measurements from the ACC area had higher CVs than the Broca area. (CV = 6–14% versus 4–7%). Conclusion: Measurement in the Broca area yields better reproducibility than the ACC. With appropriate acquisition times and preprocessing tools, measurements from the ACC area are also reliable. Level of Evidence : 1 Technical Efficacy : Stage 1 J. MAGN. RESON. IMAGING 2017;46:421–430 … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 46:Issue 2(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 46:Issue 2(2017)
- Issue Display:
- Volume 46, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 2
- Issue Sort Value:
- 2017-0046-0002-0000
- Page Start:
- 421
- Page End:
- 430
- Publication Date:
- 2017-02-15
- Subjects:
- MRS -- MEGA‐PRESS -- GABA -- reproducibility
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25588 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2907.xml