A pre and post evaluation of indoor air quality, ventilation, and thermal comfort in retrofitted co-operative social housing. (September 2017)
- Record Type:
- Journal Article
- Title:
- A pre and post evaluation of indoor air quality, ventilation, and thermal comfort in retrofitted co-operative social housing. (September 2017)
- Main Title:
- A pre and post evaluation of indoor air quality, ventilation, and thermal comfort in retrofitted co-operative social housing
- Authors:
- Broderick, Áine
Byrne, Miriam
Armstrong, Sean
Sheahan, Jerome
Coggins, Ann Marie - Abstract:
- Abstract: In comparison to building energy performance, assessment of the impact of energy upgrades on indoor air quality and occupant comfort has received little attention. Concentrations of indoor air pollutants in fifteen, three bed semi-detached co-operative social dwellings were monitored before and after an energy upgrade during the winter periods of 2015 and 2016. The fifteen dwellings consisted of seven cavity wall (CW) dwellings and eight hollow block (HB) wall dwellings. Concentrations of indoor air pollutants including CO, PM2.5, CO2, TVOCs, formaldehyde, BTEX, NO2 and thermal parameters including temperature and relative humidity, were measured in the main living area and main bedroom before and after the energy upgrade. Building air tightness decreased from pre retrofit values of 9.26–10.00m 3 /(h.m 2 ) @ 50 Pato an average of 5.53 m 3 /(h.m 2 ) @ 50 Pa and 8.61m 3 /(h.m 2 ) @ 50 Pa post retrofit (CW group and HB group, respectively). Concentrations of CO2, TVOC, and PM2.5 significantly changed post-retrofit, increasing post retrofit in both dwelling groups (CW; p = 0.014; p = 0.009; p = 0.005) (HB; p = 0.003; p = 0.032; p = 0.008). Increases in pollutant concentrations were correlated with lower building air exchange rates post retrofit. This study suggests that the energy retrofit had a positive impact on occupant comfort and building temperature; however, concentrations of some pollutants were found to increase following the retrofit. The study highlights theAbstract: In comparison to building energy performance, assessment of the impact of energy upgrades on indoor air quality and occupant comfort has received little attention. Concentrations of indoor air pollutants in fifteen, three bed semi-detached co-operative social dwellings were monitored before and after an energy upgrade during the winter periods of 2015 and 2016. The fifteen dwellings consisted of seven cavity wall (CW) dwellings and eight hollow block (HB) wall dwellings. Concentrations of indoor air pollutants including CO, PM2.5, CO2, TVOCs, formaldehyde, BTEX, NO2 and thermal parameters including temperature and relative humidity, were measured in the main living area and main bedroom before and after the energy upgrade. Building air tightness decreased from pre retrofit values of 9.26–10.00m 3 /(h.m 2 ) @ 50 Pato an average of 5.53 m 3 /(h.m 2 ) @ 50 Pa and 8.61m 3 /(h.m 2 ) @ 50 Pa post retrofit (CW group and HB group, respectively). Concentrations of CO2, TVOC, and PM2.5 significantly changed post-retrofit, increasing post retrofit in both dwelling groups (CW; p = 0.014; p = 0.009; p = 0.005) (HB; p = 0.003; p = 0.032; p = 0.008). Increases in pollutant concentrations were correlated with lower building air exchange rates post retrofit. This study suggests that the energy retrofit had a positive impact on occupant comfort and building temperature; however, concentrations of some pollutants were found to increase following the retrofit. The study highlights the importance of characterising indoor air quality post energy retrofits within the overall building energy performance to ensure improved health outcomes for building occupants post retrofit. Highlights: Measured priority indoor pollutants before and after an energy upgrade. Observation that energy retrofit had a positive impact on occupant comfort and building temperature. Highlights the importance of evaluating ventilation strategies as part of the retrofit. … (more)
- Is Part Of:
- Building and environment. Volume 122(2017)
- Journal:
- Building and environment
- Issue:
- Volume 122(2017)
- Issue Display:
- Volume 122, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 122
- Issue:
- 2017
- Issue Sort Value:
- 2017-0122-2017-0000
- Page Start:
- 126
- Page End:
- 133
- Publication Date:
- 2017-09
- Subjects:
- Indoor air quality -- Occupant comfort -- Renovation -- Semi-detached dwellings -- Social housing -- Ventilation -- Energy retrofit
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2017.05.020 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2921.xml