Airborne fungal species associated with mouldy and non-mouldy buildings – effects of air change rates, humidity, and air velocity. (September 2017)
- Record Type:
- Journal Article
- Title:
- Airborne fungal species associated with mouldy and non-mouldy buildings – effects of air change rates, humidity, and air velocity. (September 2017)
- Main Title:
- Airborne fungal species associated with mouldy and non-mouldy buildings – effects of air change rates, humidity, and air velocity
- Authors:
- Knudsen, Sofie M.
Gunnarsen, Lars
Madsen, Anne Mette - Abstract:
- Abstract: Several studies have shown an association between dampness and health issues like headache and asthma. To better understand the exposure risk of fungal growth in buildings this study investigates the release of fungi from gypsum boards infested with fungi from a moisture-damaged house. Further, the composition and concentration of fungal species in indoor air of five non-moisture-damaged homes are analysed, and the ratio between species associated- and not associated with moisture-damaged buildings are related to air change rate (ACR) and relative humidity (RH). The air velocity near the surface of the gypsum boards in combination with the changes in sampling time influenced the particle release rate. After 8 h particles were still released, and more species were released during 8 h with low air velocity than during 15 min with high air velocity. More fungal species and a higher release rate were found from damp surfaces with substantial growth than from gypsum boards dried out before they were totally colonized. In the five homes ACR and RH had a significant influence on the fungal species composition. Thus, a low ACR and a high RH were associated with increased ratio of species associated with moisture-damage relative to species not associated with moisture-damage. In conclusion, increasing the ventilation and reducing the RH of the indoor air will have a beneficial effect on the airborne species composition. Further, fast action by drying out a fungalAbstract: Several studies have shown an association between dampness and health issues like headache and asthma. To better understand the exposure risk of fungal growth in buildings this study investigates the release of fungi from gypsum boards infested with fungi from a moisture-damaged house. Further, the composition and concentration of fungal species in indoor air of five non-moisture-damaged homes are analysed, and the ratio between species associated- and not associated with moisture-damaged buildings are related to air change rate (ACR) and relative humidity (RH). The air velocity near the surface of the gypsum boards in combination with the changes in sampling time influenced the particle release rate. After 8 h particles were still released, and more species were released during 8 h with low air velocity than during 15 min with high air velocity. More fungal species and a higher release rate were found from damp surfaces with substantial growth than from gypsum boards dried out before they were totally colonized. In the five homes ACR and RH had a significant influence on the fungal species composition. Thus, a low ACR and a high RH were associated with increased ratio of species associated with moisture-damage relative to species not associated with moisture-damage. In conclusion, increasing the ventilation and reducing the RH of the indoor air will have a beneficial effect on the airborne species composition. Further, fast action by drying out a fungal infestation has a positive impact on the exposure risk in terms of exposure level and species composition. Highlights: ACR and RH influence the fungal species composition indoors. Damp associated fungi are associated with the seasons autumn and winter. Larger air velocity near infested surfaces increases the fungal particle release. Fast action in the remediation process influences the potential exposure risk. … (more)
- Is Part Of:
- Building and environment. Volume 122(2017)
- Journal:
- Building and environment
- Issue:
- Volume 122(2017)
- Issue Display:
- Volume 122, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 122
- Issue:
- 2017
- Issue Sort Value:
- 2017-0122-2017-0000
- Page Start:
- 161
- Page End:
- 170
- Publication Date:
- 2017-09
- Subjects:
- Airborne fungal exposure -- ERMI -- Release rate -- Air change rate -- Species composition -- Water damage
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2017.06.017 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2920.xml