Direct measurement of clinical mammographic x‐ray spectra using a CdTe spectrometer. Issue 7 (26th May 2017)
- Record Type:
- Journal Article
- Title:
- Direct measurement of clinical mammographic x‐ray spectra using a CdTe spectrometer. Issue 7 (26th May 2017)
- Main Title:
- Direct measurement of clinical mammographic x‐ray spectra using a CdTe spectrometer
- Authors:
- Santos, Josilene C.
Tomal, Alessandra
Furquim, Tânia A.
Fausto, Agnes M. F.
Nogueira, Maria S.
Costa, Paulo R. - Abstract:
- Abstract : Purpose: To introduce and evaluate a method developed for the direct measurement of mammographic x‐ray spectra using a CdTe spectrometer. The assembly of a positioning system and the design of a simple and customized alignment device for this application is described. Methods: A positioning system was developed to easily and accurately locate the CdTe detector in the x‐ray beam. Additionally, an alignment device to line up the detector with the central axis of the radiation beam was designed. Direct x‐ray spectra measurements were performed in two different clinical mammography units and the measured x‐ray spectra were compared with computer‐generated spectra. In addition, the spectrometer misalignment effect was evaluated by comparing the measured spectra when this device is aligned relatively to when it is misaligned. Results: The positioning and alignment of the spectrometer have allowed the measurements of direct mammographic x‐ray spectra in agreement with computer‐generated spectra. The most accurate x‐ray spectral shape, related with the minimal HVL value, and high photon fluence for measured spectra was found with the spectrometer aligned according to the proposed method. The HVL values derived from both simulated and measured x‐ray spectra differ at most 1.3 and 4.5% for two mammography devices evaluated in this study. Conclusion: The experimental method developed in this work allows simple positioning and alignment of a spectrometer for x‐ray spectraAbstract : Purpose: To introduce and evaluate a method developed for the direct measurement of mammographic x‐ray spectra using a CdTe spectrometer. The assembly of a positioning system and the design of a simple and customized alignment device for this application is described. Methods: A positioning system was developed to easily and accurately locate the CdTe detector in the x‐ray beam. Additionally, an alignment device to line up the detector with the central axis of the radiation beam was designed. Direct x‐ray spectra measurements were performed in two different clinical mammography units and the measured x‐ray spectra were compared with computer‐generated spectra. In addition, the spectrometer misalignment effect was evaluated by comparing the measured spectra when this device is aligned relatively to when it is misaligned. Results: The positioning and alignment of the spectrometer have allowed the measurements of direct mammographic x‐ray spectra in agreement with computer‐generated spectra. The most accurate x‐ray spectral shape, related with the minimal HVL value, and high photon fluence for measured spectra was found with the spectrometer aligned according to the proposed method. The HVL values derived from both simulated and measured x‐ray spectra differ at most 1.3 and 4.5% for two mammography devices evaluated in this study. Conclusion: The experimental method developed in this work allows simple positioning and alignment of a spectrometer for x‐ray spectra measurements given the geometrical constraints and maintenance of the original configurations of mammography machines. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 7(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 7(2017)
- Issue Display:
- Volume 44, Issue 7 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 7
- Issue Sort Value:
- 2017-0044-0007-0000
- Page Start:
- 3504
- Page End:
- 3511
- Publication Date:
- 2017-05-26
- Subjects:
- CdTe detector -- detector alignment -- mammography -- spectrometry
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12287 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2911.xml