Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath‐hold. Issue 2 (5th June 2017)
- Record Type:
- Journal Article
- Title:
- Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath‐hold. Issue 2 (5th June 2017)
- Main Title:
- Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath‐hold
- Authors:
- Weingärtner, Sebastian
Moeller, Steen
Schmitter, Sebastian
Auerbach, Edward
Kellman, Peter
Shenoy, Chetan
Akçakaya, Mehmet - Abstract:
- Abstract : Purpose: To develop a saturation recovery myocardial T1 mapping method for the simultaneous multislice acquisition of three slices. Methods: Saturation pulse‐prepared heart rate independent inversion recovery (SAPPHIRE) T1 mapping was implemented with simultaneous multislice imaging using FLASH readouts for faster coverage of the myocardium. Controlled aliasing in parallel imaging (CAIPI) was used to achieve minimal noise amplification in three slices. Multiband reconstruction was performed using three linear reconstruction methods: Slice‐ and in‐plane GRAPPA, CG‐SENSE, and Tikhonov‐regularized CG‐SENSE. Accuracy, spatial variability, and interslice leakage were compared with single‐band T1 mapping in a phantom and in six healthy subjects. Results: Multiband phantom T1 times showed good agreement with single‐band T1 mapping for all three reconstruction methods (normalized root mean square error <1.0%). The increase in spatial variability compared with single‐band imaging was lowest for GRAPPA (1.29‐fold), with higher penalties for Tikhonov‐regularized CG‐SENSE (1.47‐fold) and CG‐SENSE (1.52‐fold). In vivo multiband T1 times showed no significant difference compared with single‐band (T1 time ± intersegmental variability: single‐band, 1580 ± 119 ms; GRAPPA, 1572 ± 145 ms; CG‐SENSE, 1579 ± 159 ms; Tikhonov, 1586 ± 150 ms [analysis of variance; P = 0.86]). Interslice leakage was smallest for GRAPPA (5.4%) and higher for CG‐SENSE (6.2%) and Tikhonov‐regularizedAbstract : Purpose: To develop a saturation recovery myocardial T1 mapping method for the simultaneous multislice acquisition of three slices. Methods: Saturation pulse‐prepared heart rate independent inversion recovery (SAPPHIRE) T1 mapping was implemented with simultaneous multislice imaging using FLASH readouts for faster coverage of the myocardium. Controlled aliasing in parallel imaging (CAIPI) was used to achieve minimal noise amplification in three slices. Multiband reconstruction was performed using three linear reconstruction methods: Slice‐ and in‐plane GRAPPA, CG‐SENSE, and Tikhonov‐regularized CG‐SENSE. Accuracy, spatial variability, and interslice leakage were compared with single‐band T1 mapping in a phantom and in six healthy subjects. Results: Multiband phantom T1 times showed good agreement with single‐band T1 mapping for all three reconstruction methods (normalized root mean square error <1.0%). The increase in spatial variability compared with single‐band imaging was lowest for GRAPPA (1.29‐fold), with higher penalties for Tikhonov‐regularized CG‐SENSE (1.47‐fold) and CG‐SENSE (1.52‐fold). In vivo multiband T1 times showed no significant difference compared with single‐band (T1 time ± intersegmental variability: single‐band, 1580 ± 119 ms; GRAPPA, 1572 ± 145 ms; CG‐SENSE, 1579 ± 159 ms; Tikhonov, 1586 ± 150 ms [analysis of variance; P = 0.86]). Interslice leakage was smallest for GRAPPA (5.4%) and higher for CG‐SENSE (6.2%) and Tikhonov‐regularized CG‐SENSE (7.9%). Conclusion: Multiband accelerated myocardial T1 mapping demonstrated the potential for single–breath‐hold T1 quantification in 16 American Heart Association segments over three slices. A 1.2‐ to 1.4‐fold higher in vivo spatial variability was observed, where GRAPPA‐based reconstruction showed the highest homogeneity and the least interslice leakage. Magn Reson Med 78:462–471, 2017. © 2017 International Society for Magnetic Resonance in Medicine … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 78:Issue 2(2017)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 78:Issue 2(2017)
- Issue Display:
- Volume 78, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 78
- Issue:
- 2
- Issue Sort Value:
- 2017-0078-0002-0000
- Page Start:
- 462
- Page End:
- 471
- Publication Date:
- 2017-06-05
- Subjects:
- myocardial T1 mapping -- simultaneous multislice imaging -- multiband -- saturation recovery -- SAPPHIRE
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26770 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2909.xml