Retrofit of heat exchanger networks with heat transfer enhancement based on an area ratio approach. (1st March 2016)
- Record Type:
- Journal Article
- Title:
- Retrofit of heat exchanger networks with heat transfer enhancement based on an area ratio approach. (1st March 2016)
- Main Title:
- Retrofit of heat exchanger networks with heat transfer enhancement based on an area ratio approach
- Authors:
- Akpomiemie, Mary O.
Smith, Robin - Abstract:
- Highlights: Cost-effective retrofit based on area ratio approach is proposed. Energy performance is improved by the use of heat transfer enhancement. Fixed network topology and no need for additional heat transfer area in retrofit. Analysis is dependent on heat exchanger geometry. Abstract: The goal for performing heat exchanger network (HEN) retrofit is not only to reduce utility consumption but to ensure that the retrofit is economically viable. The problem of using heat transfer enhancement for retrofit lies with the uncertainty of the best location in which to apply enhancement, the augmentation level and dealing with downstream effects after enhancement is conducted. To solve these problems, a systematic methodology is proposed. The first step in this methodology is the identification of candidate heat exchangers. In the second step, two methods, sensitivity analysis and an area ratio approach are compared for the identification of the best candidate heat exchangers to enhance. Heat transfer enhancement is then performed on the best candidate heat exchanger and, a non-linear optimisation based model is used to deal with the downstream effects after enhancement, subject to meeting set constraints on the HEN, such as the stream target temperatures and heat transfer area. Following this approach, the problems posed by the use of enhancement for retrofit can be addressed in a simple and computationally inexpensive manner. Heat transfer enhancement is an attractive optionHighlights: Cost-effective retrofit based on area ratio approach is proposed. Energy performance is improved by the use of heat transfer enhancement. Fixed network topology and no need for additional heat transfer area in retrofit. Analysis is dependent on heat exchanger geometry. Abstract: The goal for performing heat exchanger network (HEN) retrofit is not only to reduce utility consumption but to ensure that the retrofit is economically viable. The problem of using heat transfer enhancement for retrofit lies with the uncertainty of the best location in which to apply enhancement, the augmentation level and dealing with downstream effects after enhancement is conducted. To solve these problems, a systematic methodology is proposed. The first step in this methodology is the identification of candidate heat exchangers. In the second step, two methods, sensitivity analysis and an area ratio approach are compared for the identification of the best candidate heat exchangers to enhance. Heat transfer enhancement is then performed on the best candidate heat exchanger and, a non-linear optimisation based model is used to deal with the downstream effects after enhancement, subject to meeting set constraints on the HEN, such as the stream target temperatures and heat transfer area. Following this approach, the problems posed by the use of enhancement for retrofit can be addressed in a simple and computationally inexpensive manner. Heat transfer enhancement is an attractive option for HEN retrofit as it can provide energy saving without the need for topology modifications and additional heat transfer area with an added benefit of reduced implementation time, as modifications can be carried out during normal shutdown periods. … (more)
- Is Part Of:
- Applied energy. Volume 165(2016)
- Journal:
- Applied energy
- Issue:
- Volume 165(2016)
- Issue Display:
- Volume 165, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 165
- Issue:
- 2016
- Issue Sort Value:
- 2016-0165-2016-0000
- Page Start:
- 22
- Page End:
- 35
- Publication Date:
- 2016-03-01
- Subjects:
- Heat exchanger network -- Retrofit -- Heat transfer enhancement -- Optimisation -- Area ratio -- Sensitivity analysis
Power (Mechanics) -- Periodicals
Energy conservation -- Periodicals
Energy conversion -- Periodicals
621.042 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03062619 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apenergy.2015.11.056 ↗
- Languages:
- English
- ISSNs:
- 0306-2619
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1572.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2904.xml