Effects of pupil dilation on MAIA microperimetry. (24th January 2017)
- Record Type:
- Journal Article
- Title:
- Effects of pupil dilation on MAIA microperimetry. (24th January 2017)
- Main Title:
- Effects of pupil dilation on MAIA microperimetry
- Authors:
- Han, Ruofan C
Jolly, Jasleen K
Xue, Kanmin
MacLaren, Robert E - Abstract:
- Abstract: Background: Macular Integrity Assessment microperimetry assesses macular sensitivity to projected point light sources and maps eye movements to assess fixation stability. Although microperimetry is gaining prominence as an assessment tool in clinical and research settings, there is no consensus on whether it should be performed before or after pupil dilation. No studies to date have examined the effect of pupil dilation on results. The aim of this project was to elucidate the effect of pupil dilation on microperimetry outcomes. Design: Prospective audit. Participants: Twenty healthy patients from postoperative cataract clinic and 10 patients with choroideremia to simulate a disease with peripheral visual field loss. Methods: Subjects underwent 10–2 68‐point field testing using the Macular Integrity Assessment microperimeter on each eye. Subjects then underwent randomized dilation of one eye, and the test was repeated in both eyes. Main Outcome Measures: We compared changes in threshold sensitivity and fixation stability pre‐pupil and post‐pupil dilation. The undilated eye was analysed for any learning or fatigue effect caused by test repetition. Results: Dilation produced no significant effect on threshold sensitivity (dilation effect: −0.29 decibels, P = 0.23) or fixation stability in healthy controls or in choroideremia patients (dilation effect: +0.08log bivariate contour ellipse area, P = 0.14). There was also no significant learning effect seen in theAbstract: Background: Macular Integrity Assessment microperimetry assesses macular sensitivity to projected point light sources and maps eye movements to assess fixation stability. Although microperimetry is gaining prominence as an assessment tool in clinical and research settings, there is no consensus on whether it should be performed before or after pupil dilation. No studies to date have examined the effect of pupil dilation on results. The aim of this project was to elucidate the effect of pupil dilation on microperimetry outcomes. Design: Prospective audit. Participants: Twenty healthy patients from postoperative cataract clinic and 10 patients with choroideremia to simulate a disease with peripheral visual field loss. Methods: Subjects underwent 10–2 68‐point field testing using the Macular Integrity Assessment microperimeter on each eye. Subjects then underwent randomized dilation of one eye, and the test was repeated in both eyes. Main Outcome Measures: We compared changes in threshold sensitivity and fixation stability pre‐pupil and post‐pupil dilation. The undilated eye was analysed for any learning or fatigue effect caused by test repetition. Results: Dilation produced no significant effect on threshold sensitivity (dilation effect: −0.29 decibels, P = 0.23) or fixation stability in healthy controls or in choroideremia patients (dilation effect: +0.08log bivariate contour ellipse area, P = 0.14). There was also no significant learning effect seen in the undilated eye, with no improvement in threshold sensitivity (order of eye testing: +0.03log bivariate contour ellipse area, P = 0.71). Conclusions: In the clinical setting, patients may be tested for 10 degree microperimetry with or without pupil dilation, as both scenarios yield consistent and interchangeable results. … (more)
- Is Part Of:
- Clinical & experimental ophthalmology. Volume 45:Number 5(2017)
- Journal:
- Clinical & experimental ophthalmology
- Issue:
- Volume 45:Number 5(2017)
- Issue Display:
- Volume 45, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 5
- Issue Sort Value:
- 2017-0045-0005-0000
- Page Start:
- 489
- Page End:
- 495
- Publication Date:
- 2017-01-24
- Subjects:
- dilation -- MAIA -- microperimetry -- retinal sensitivity
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1442-6404&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ceo.12907 ↗
- Languages:
- English
- ISSNs:
- 1442-6404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.251920
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2889.xml