A study of IMRT planning parameters on planning efficiency, delivery efficiency, and plan quality. Issue 6 (13th May 2013)
- Record Type:
- Journal Article
- Title:
- A study of IMRT planning parameters on planning efficiency, delivery efficiency, and plan quality. Issue 6 (13th May 2013)
- Main Title:
- A study of IMRT planning parameters on planning efficiency, delivery efficiency, and plan quality
- Authors:
- Mittauer, Kathryn
Lu, Bo
Yan, Guanghua
Kahler, Darren
Gopal, Arun
Amdur, Robert
Liu, Chihray - Abstract:
- Abstract : Purpose: : To improve planning and delivery efficiency of head and neck IMRT without compromising planning quality through the evaluation of inverse planning parameters. Methods: : Eleven head and neck patients with pre‐existing IMRT treatment plans were selected for this retrospective study. The Pinnacle treatment planning system (TPS) was used to compute new treatment plans for each patient by varying the individual or the combined parameters of dose/fluence grid resolution, minimum MU per segment, and minimum segment area. Forty‐five plans per patient were generated with the following variations: 4 dose/fluence grid resolution plans, 12 minimum segment area plans, 9 minimum MU plans, and 20 combined minimum segment area/minimum MU plans. Each plan was evaluated and compared to others based on dose volume histograms (DVHs) (i.e., plan quality), planning time, and delivery time. To evaluate delivery efficiency, a model was developed that estimated the delivery time of a treatment plan, and validated through measurements on an Elekta Synergy linear accelerator. Results: : The uncertainty (i.e., variation) of the dose‐volume index due to dose calculation grid variation was as high as 8.2% (5.5 Gy in absolute dose) for planning target volumes (PTVs) and 13.3% (2.1 Gy in absolute dose) for planning at risk volumes (PRVs). Comparison results of dose distributions indicated that smaller volumes were more susceptible to uncertainties. The grid resolution of a 4 mm doseAbstract : Purpose: : To improve planning and delivery efficiency of head and neck IMRT without compromising planning quality through the evaluation of inverse planning parameters. Methods: : Eleven head and neck patients with pre‐existing IMRT treatment plans were selected for this retrospective study. The Pinnacle treatment planning system (TPS) was used to compute new treatment plans for each patient by varying the individual or the combined parameters of dose/fluence grid resolution, minimum MU per segment, and minimum segment area. Forty‐five plans per patient were generated with the following variations: 4 dose/fluence grid resolution plans, 12 minimum segment area plans, 9 minimum MU plans, and 20 combined minimum segment area/minimum MU plans. Each plan was evaluated and compared to others based on dose volume histograms (DVHs) (i.e., plan quality), planning time, and delivery time. To evaluate delivery efficiency, a model was developed that estimated the delivery time of a treatment plan, and validated through measurements on an Elekta Synergy linear accelerator. Results: : The uncertainty (i.e., variation) of the dose‐volume index due to dose calculation grid variation was as high as 8.2% (5.5 Gy in absolute dose) for planning target volumes (PTVs) and 13.3% (2.1 Gy in absolute dose) for planning at risk volumes (PRVs). Comparison results of dose distributions indicated that smaller volumes were more susceptible to uncertainties. The grid resolution of a 4 mm dose grid with a 2 mm fluence grid was recommended, since it can reduce the final dose calculation time by 63% compared to the accepted standard (2 mm dose grid with a 2 mm fluence grid resolution) while maintaining a similar level of dose‐volume index variation. Threshold values that maintained adequate plan quality (DVH results of the PTVs and PRVs remained satisfied for their dose objectives) were 5 cm 2 for minimum segment area and 5 MU for minimum MU. As the minimum MU parameter was increased, the number of segments and delivery time were decreased. Increasing the minimum segment area parameter decreased the plan MU, but had less of an effect on the number of segments and delivery time. Our delivery time model predicted delivery time to within 1.8%. Conclusions: : Increasing the dose grid while maintaining a small fluence grid allows for improved planning efficiency without compromising plan quality. Delivery efficiency can be improved by increasing the minimum MU, but not the minimum segment area. However, increasing the respective minimum MU and/or the minimum segment area to any value greater than 5 MU and 5 cm 2 is not recommended because it degrades plan quality. … (more)
- Is Part Of:
- Medical physics. Volume 40:Issue 6(2013)
- Journal:
- Medical physics
- Issue:
- Volume 40:Issue 6(2013)
- Issue Display:
- Volume 40, Issue 6 (2013)
- Year:
- 2013
- Volume:
- 40
- Issue:
- 6
- Issue Sort Value:
- 2013-0040-0006-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2013-05-13
- Subjects:
- Treatment planning -- Dose‐volume analysis -- Quality assurance in radiotherapy -- Accelerators
biomedical measurement -- dosimetry -- linear accelerators -- planning -- radiation therapy
IMRT -- plan quality -- delivery time -- treatment planning
Measuring for diagnostic purposes; Identification of persons -- Radiation therapy -- Linear accelerators
Dosimetry -- Intensity modulated radiation therapy -- Multileaf collimators -- Linear accelerators -- Time measurement -- Cancer -- Radiation treatment -- Medical treatment planning -- Drug delivery -- Sequence analysis
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4803460 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2886.xml