Examination of a deformable motion model for respiratory movements and 4D dose calculations using different driving surrogates. Issue 6 (12th May 2017)
- Record Type:
- Journal Article
- Title:
- Examination of a deformable motion model for respiratory movements and 4D dose calculations using different driving surrogates. Issue 6 (12th May 2017)
- Main Title:
- Examination of a deformable motion model for respiratory movements and 4D dose calculations using different driving surrogates
- Authors:
- Wölfelschneider, Jens
Seregni, Matteo
Fassi, Aurora
Ziegler, Marc
Baroni, Guido
Fietkau, Rainer
Riboldi, Marco
Bert, Christoph - Abstract:
- Abstract : Purpose: The aim of this study was to evaluate a surrogate‐driven motion model based on four‐dimensional computed tomography that is able to predict CT volumes corresponding to arbitrary respiratory phases. Furthermore, the comparison of three different driving surrogates is examined and the feasibility of using the model for 4D dose re‐calculation will be discussed. Methods: The study is based on repeated 4DCTs of twenty patients treated for bronchial carcinoma and metastasis. The motion model was estimated from the planning 4DCT through deformable image registration. To predict a certain phase of a follow‐up 4DCT, the model considers inter‐fractional variations (baseline correction) and intra‐fractional respiratory parameters (amplitude and phase) derived from surrogates. The estimated volumes resulting from the model were compared to ground‐truth clinical 4DCTs using absolute HU differences in the lung region and landmarks localized using the Scale Invariant Feature Transform. Finally, the γ ‐index was used to evaluate the dosimetric effects of the intensity differences measured between the estimated and the ground‐truth CT volumes. Results: The results show absolute HU differences between estimated and ground‐truth images with median value (± standard deviation) of (61.3 ± 16.7) HU. Median 3D distances, measured on about 400 matching landmarks in each volume, were (2.9 ± 3.0) mm. 3D errors up to 28.2 mm were found for CT images with artifacts or reducedAbstract : Purpose: The aim of this study was to evaluate a surrogate‐driven motion model based on four‐dimensional computed tomography that is able to predict CT volumes corresponding to arbitrary respiratory phases. Furthermore, the comparison of three different driving surrogates is examined and the feasibility of using the model for 4D dose re‐calculation will be discussed. Methods: The study is based on repeated 4DCTs of twenty patients treated for bronchial carcinoma and metastasis. The motion model was estimated from the planning 4DCT through deformable image registration. To predict a certain phase of a follow‐up 4DCT, the model considers inter‐fractional variations (baseline correction) and intra‐fractional respiratory parameters (amplitude and phase) derived from surrogates. The estimated volumes resulting from the model were compared to ground‐truth clinical 4DCTs using absolute HU differences in the lung region and landmarks localized using the Scale Invariant Feature Transform. Finally, the γ ‐index was used to evaluate the dosimetric effects of the intensity differences measured between the estimated and the ground‐truth CT volumes. Results: The results show absolute HU differences between estimated and ground‐truth images with median value (± standard deviation) of (61.3 ± 16.7) HU. Median 3D distances, measured on about 400 matching landmarks in each volume, were (2.9 ± 3.0) mm. 3D errors up to 28.2 mm were found for CT images with artifacts or reduced quality. Pass rates for all surrogate approaches were above 98.9% with a γ ‐criterion of 2%/2 mm. Conclusion: The results depend mainly on the image quality of the initial 4DCT and the deformable image registration. All investigated surrogates can be used to estimate follow‐up 4DCT phases, however, uncertainties decrease for volumetric approaches. Application of the model for 4D dose calculations is feasible. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 6(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 6(2017)
- Issue Display:
- Volume 44, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 6
- Issue Sort Value:
- 2017-0044-0006-0000
- Page Start:
- 2066
- Page End:
- 2076
- Publication Date:
- 2017-05-12
- Subjects:
- 4D dose reconstruction -- 4DCT -- respiratory motion model -- scale invariant feature transform -- surrogates
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12243 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2893.xml