Validation rules for blood smear revision after automated hematological testing using Mindray CAL‐8000. Issue 4 (6th October 2016)
- Record Type:
- Journal Article
- Title:
- Validation rules for blood smear revision after automated hematological testing using Mindray CAL‐8000. Issue 4 (6th October 2016)
- Main Title:
- Validation rules for blood smear revision after automated hematological testing using Mindray CAL‐8000
- Authors:
- Buoro, Sabrina
Mecca, Tommaso
Seghezzi, Michela
Manenti, Barbara
Azzarà, Giovanna
Ottomano, Cosimo
Lippi, Giuseppe - Abstract:
- Abstract : Background: This article was aimed to test the use of validation rules for blood smear review after automated hematological testing using Mindray CAL‐8000 (two hematological analyzers and one autoslider). Methods: This study was based on 1013 peripheral blood samples (PB) referred for routine hematological testing. Results of testing on CAL‐8000 were analyzed using both locally derived and International Consensus Group for Hematology (ICGH) validation rules, and then compared with data obtained by optical microscopy (OM). A workflow analysis was also completed. Results: The overall agreement with locally derived and ICGH criteria was 91% and 85%, but a higher sensitivity was observed for locally derived criteria (0.97 vs 0.95). The percentage of false negative and false positive samples was 2.1% and 7.1% using ICGH criteria, and was 1.4% and 14% using locally defined rules. The throughput of CAL‐8000 system was 208 samples/h, with a percentage of OM analysis comprised between 14% and 17%, and sensitivity of 0.97. As regards personnel activity, we estimated 0.8 full‐time equivalent (FTE) of technical staff and 0.7 FTE of personnel for clinical validation of data and blood smear review. Conclusion: These results show that customization of validation rules is necessary for enhancing the quality of hematological testing and optimizing workflow.
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 31:Issue 4(2017:Jul.)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 31:Issue 4(2017:Jul.)
- Issue Display:
- Volume 31, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 4
- Issue Sort Value:
- 2017-0031-0004-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2016-10-06
- Subjects:
- automated count -- hematological testing -- optical microscopy -- rules
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22067 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2868.xml