Automated hybrid closed‐loop control with a proportional‐integral‐derivative based system in adolescents and adults with type 1 diabetes: individualizing settings for optimal performance. Issue 5 (18th May 2016)
- Record Type:
- Journal Article
- Title:
- Automated hybrid closed‐loop control with a proportional‐integral‐derivative based system in adolescents and adults with type 1 diabetes: individualizing settings for optimal performance. Issue 5 (18th May 2016)
- Main Title:
- Automated hybrid closed‐loop control with a proportional‐integral‐derivative based system in adolescents and adults with type 1 diabetes: individualizing settings for optimal performance
- Authors:
- Ly, Trang T.
Weinzimer, Stuart A.
Maahs, David M.
Sherr, Jennifer L.
Roy, Anirban
Grosman, Benyamin
Cantwell, Martin
Kurtz, Natalie
Carria, Lori
Messer, Laurel
von Eyben, Rie
Buckingham, Bruce A. - Abstract:
- Abstract: Background: Automated insulin delivery systems, utilizing a control algorithm to dose insulin based upon subcutaneous continuous glucose sensor values and insulin pump therapy, will soon be available for commercial use. The objective of this study was to determine the preliminary safety and efficacy of initialization parameters with the Medtronic hybrid closed‐loop controller by comparing percentage of time in range, 70–180 mg/dL (3.9–10 mmol/L), mean glucose values, as well as percentage of time above and below target range between sensor‐augmented pump therapy and hybrid closed‐loop, in adults and adolescents with type 1 diabetes. Methods: We studied an initial cohort of 9 adults followed by a second cohort of 15 adolescents, using the Medtronic hybrid closed‐loop system with the proportional‐integral‐derivative with insulin feed‐back (PID‐IFB) algorithm. Hybrid closed‐loop was tested in supervised hotel‐based studies over 4–5 days. Results: The overall mean percentage of time in range (70–180 mg/dL, 3.9–10 mmol/L) during hybrid closed‐loop was 71.8% in the adult cohort and 69.8% in the adolescent cohort. The overall percentage of time spent under 70 mg/dL (3.9 mmol/L) was 2.0% in the adult cohort and 2.5% in the adolescent cohort. Mean glucose values were 152 mg/dL (8.4 mmol/L) in the adult cohort and 153 mg/dL (8.5 mmol/L) in the adolescent cohort. Conclusions: Closed‐loop control using the Medtronic hybrid closed‐loop system enables adaptive, real‐time basalAbstract: Background: Automated insulin delivery systems, utilizing a control algorithm to dose insulin based upon subcutaneous continuous glucose sensor values and insulin pump therapy, will soon be available for commercial use. The objective of this study was to determine the preliminary safety and efficacy of initialization parameters with the Medtronic hybrid closed‐loop controller by comparing percentage of time in range, 70–180 mg/dL (3.9–10 mmol/L), mean glucose values, as well as percentage of time above and below target range between sensor‐augmented pump therapy and hybrid closed‐loop, in adults and adolescents with type 1 diabetes. Methods: We studied an initial cohort of 9 adults followed by a second cohort of 15 adolescents, using the Medtronic hybrid closed‐loop system with the proportional‐integral‐derivative with insulin feed‐back (PID‐IFB) algorithm. Hybrid closed‐loop was tested in supervised hotel‐based studies over 4–5 days. Results: The overall mean percentage of time in range (70–180 mg/dL, 3.9–10 mmol/L) during hybrid closed‐loop was 71.8% in the adult cohort and 69.8% in the adolescent cohort. The overall percentage of time spent under 70 mg/dL (3.9 mmol/L) was 2.0% in the adult cohort and 2.5% in the adolescent cohort. Mean glucose values were 152 mg/dL (8.4 mmol/L) in the adult cohort and 153 mg/dL (8.5 mmol/L) in the adolescent cohort. Conclusions: Closed‐loop control using the Medtronic hybrid closed‐loop system enables adaptive, real‐time basal rate modulation. Initializing hybrid closed‐loop in clinical practice will involve individualizing initiation parameters to optimize overall glucose control. … (more)
- Is Part Of:
- Pediatric diabetes. Volume 18:Issue 5(2017)
- Journal:
- Pediatric diabetes
- Issue:
- Volume 18:Issue 5(2017)
- Issue Display:
- Volume 18, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 18
- Issue:
- 5
- Issue Sort Value:
- 2017-0018-0005-0000
- Page Start:
- 348
- Page End:
- 355
- Publication Date:
- 2016-05-18
- Subjects:
- artificial pancreas -- continuous glucose monitoring -- hybrid closed loop -- type 1 diabetes
Diabetes in children -- Periodicals
616.462 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1399-543X&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/pedi.12399 ↗
- Languages:
- English
- ISSNs:
- 1399-543X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6417.584000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2797.xml