3D delivered dose assessment using a 4DCT‐based motion model. Issue 6 (30th November 2016)
- Record Type:
- Journal Article
- Title:
- 3D delivered dose assessment using a 4DCT‐based motion model. Issue 6 (30th November 2016)
- Main Title:
- 3D delivered dose assessment using a 4DCT‐based motion model
- Authors:
- Cai, Weixing
Hurwitz, Martina H.
Williams, Christopher L.
Dhou, Salam
Berbeco, Ross I.
Seco, Joao
Mishra, Pankaj
Lewis, John H. - Abstract:
- Abstract : Purpose: The purpose of this work is to develop a clinically feasible method of calculating actual delivered dose distributions for patients who have significant respiratory motion during the course of stereotactic body radiation therapy (SBRT). Methods: A novel approach was proposed to calculate the actual delivered dose distribution for SBRT lung treatment. This approach can be specified in three steps. (1) At the treatment planning stage, a patient‐specific motion model is created from planning 4DCT data. This model assumes that the displacement vector field (DVF) of any respiratory motion deformation can be described as a linear combination of some basis DVFs. (2) During the treatment procedure, 2D time‐varying projection images (either kV or MV projections) are acquired, from which time‐varying "fluoroscopic" 3D images of the patient are reconstructed using the motion model. The DVF of each timepoint in the time‐varying reconstruction is an optimized linear combination of basis DVFs such that the 2D projection of the 3D volume at this timepoint matches the projection image. (3) 3D dose distribution is computed for each timepoint in the set of 3D reconstructed fluoroscopic images, from which the total effective 3D delivered dose is calculated by accumulating deformed dose distributions. This approach was first validated using two modified digital extended cardio‐torso (XCAT) phantoms with lung tumors and different respiratory motions. The estimated doses wereAbstract : Purpose: The purpose of this work is to develop a clinically feasible method of calculating actual delivered dose distributions for patients who have significant respiratory motion during the course of stereotactic body radiation therapy (SBRT). Methods: A novel approach was proposed to calculate the actual delivered dose distribution for SBRT lung treatment. This approach can be specified in three steps. (1) At the treatment planning stage, a patient‐specific motion model is created from planning 4DCT data. This model assumes that the displacement vector field (DVF) of any respiratory motion deformation can be described as a linear combination of some basis DVFs. (2) During the treatment procedure, 2D time‐varying projection images (either kV or MV projections) are acquired, from which time‐varying "fluoroscopic" 3D images of the patient are reconstructed using the motion model. The DVF of each timepoint in the time‐varying reconstruction is an optimized linear combination of basis DVFs such that the 2D projection of the 3D volume at this timepoint matches the projection image. (3) 3D dose distribution is computed for each timepoint in the set of 3D reconstructed fluoroscopic images, from which the total effective 3D delivered dose is calculated by accumulating deformed dose distributions. This approach was first validated using two modified digital extended cardio‐torso (XCAT) phantoms with lung tumors and different respiratory motions. The estimated doses were compared to the dose that would be calculated for routine 4DCT‐based planning and to the actual delivered dose that was calculated using "ground truth" XCAT phantoms at all timepoints. The approach was also tested using one set of patient data, which demonstrated the application of our method in a clinical scenario. Results: For the first XCAT phantom that has a mostly regular breathing pattern, the errors in 95% volume dose ( D 95) are 0.11% and 0.83%, respectively for 3D fluoroscopic images reconstructed from kV and MV projections compared to the ground truth, which is clinically comparable to 4DCT (0.093%). For the second XCAT phantom that has an irregular breathing pattern, the errors are 0.81% and 1.75% for kV and MV reconstructions, both of which are better than that of 4DCT (4.01%). In the case of real patient, although it is impossible to obtain the actual delivered dose, the dose estimation is clinically reasonable and demonstrates differences between 4DCT and MV reconstruction‐based dose estimates. Conclusions: With the availability of kV or MV projection images, the proposed approach is able to assess delivered doses for all respiratory phases during treatment. Compared to the planning dose based on 4DCT, the dose estimation using reconstructed 3D fluoroscopic images was as good as 4DCT for regular respiratory pattern and was a better dose estimation for the irregular respiratory pattern. … (more)
- Is Part Of:
- Medical physics. Volume 42:Issue 6(2015)
- Journal:
- Medical physics
- Issue:
- Volume 42:Issue 6(2015)
- Issue Display:
- Volume 42, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 6
- Issue Sort Value:
- 2015-0042-0006-0000
- Page Start:
- 2897
- Page End:
- 2907
- Publication Date:
- 2016-11-30
- Subjects:
- computerised tomography -- diagnostic radiography -- dosimetry -- image reconstruction -- medical image processing -- phantoms -- pneumodynamics -- radiation therapy
Dose‐volume analysis -- Computed tomography -- Treatment strategy
Computerised tomographs -- Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Scintigraphy
SBRT -- 4DCT -- respiratory motion -- treatment verification
Medical image reconstruction -- Cancer -- Dosimetry -- Three dimensional image processing -- Image reconstruction -- Lungs -- Image guided radiation therapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4921041 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2813.xml