Minimally Invasive Microneedle Array Electrodes Employing Direct Electron Transfer Type Glucose Dehydrogenase for the Development of Continuous Glucose Monitoring Sensors. (2017)
- Record Type:
- Journal Article
- Title:
- Minimally Invasive Microneedle Array Electrodes Employing Direct Electron Transfer Type Glucose Dehydrogenase for the Development of Continuous Glucose Monitoring Sensors. (2017)
- Main Title:
- Minimally Invasive Microneedle Array Electrodes Employing Direct Electron Transfer Type Glucose Dehydrogenase for the Development of Continuous Glucose Monitoring Sensors
- Authors:
- Sharma, Sanjiv
Takagi, Eri
Cass, Tony
Tsugawa, Wakako
Sode, Koji - Abstract:
- Abstract: Closed loop systems hinge on the accuracy and precision of the continuous glucose monitoring sensors. Most of the commercially available continuous glucose monitoring sensors is implanted subcutaneously for a period of 7-14 days. The subsequent biofouling effects have implications on the performance of the sensors over time especially at low glucose concentrations. In addition, the commercially available sensors are sensitive to the presence of interfering species such as acetaminophen in the skin compartment. We report here on the marriage of minimally invasive, continuous glucose sensors and a direct electron transfer type glucose dehydrogenase enzymatic system. Whilst the microneedles here are designed to sit in the dermal interstitial fluid over a 24-48 hour period to minimize the biofouling effect, the direct electron transfer enzyme allows operation of the electrochemical sensor at lower potentials to minimize the effect of interference. The microneedle structure design also enables the use of compensation electrodes for background subtraction to further nullify the effects of interference.
- Is Part Of:
- Procedia technology. Volume 27(2016)
- Journal:
- Procedia technology
- Issue:
- Volume 27(2016)
- Issue Display:
- Volume 27, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 27
- Issue:
- 2016
- Issue Sort Value:
- 2016-0027-2016-0000
- Page Start:
- 208
- Page End:
- 209
- Publication Date:
- 2017
- Subjects:
- continuous glucose monitoring -- minimally invasive sensors -- direct electron transfer -- microneedles
Technology -- Congresses
Technology -- Periodicals
Engineering -- Congresses
Engineering -- Periodicals
Engineering
Technology
Conference proceedings
Periodicals
605 - Journal URLs:
- http://www.sciencedirect.com/science/journal/22120173 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.protcy.2017.04.087 ↗
- Languages:
- English
- ISSNs:
- 2212-0173
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2868.xml