Evaluation of FMH QuikQuant for the detection and quantification of fetomaternal hemorrhage1. Issue 1 (26th October 2012)
- Record Type:
- Journal Article
- Title:
- Evaluation of FMH QuikQuant for the detection and quantification of fetomaternal hemorrhage1. Issue 1 (26th October 2012)
- Main Title:
- Evaluation of FMH QuikQuant for the detection and quantification of fetomaternal hemorrhage1
- Authors:
- Pastoret, Cedric
Priol, Jerome Le
Fest, Thierry
Roussel, Mikael - Abstract:
- Abstract: Background: The Kleihauer–Betke test (KBT) is the most widely used assay for fetomaternal hemorrhage (FMH) detection in rhesus D negative women. In the current study, we sought to evaluate the performance of a flow cytometry (FCM) kit (FMH QuikQuant) using an anti‐HbF antibody. Methods: Eighty‐three pregnant women, 58 umbilical cord blood (UCB) dilutions in adult blood, and 6 control samples were tested in parallel with FCM and KBT. Results: Firstly, we compared for each assay, on the 58 UCB preparations, results obtained to dilutions prepared. FCM results showed an excellent correlation ( r = 0.97), a high reproducibility with a coefficient of variation lower than 20% for values reaching 10 fetal RBCs. KBT values were correlated ( r = 0.94) but exhibited a poor reproducibility. Then, we compared both techniques on all samples. FCM showed a good correlation with KBT ( r = 0.87) but the KBT exhibited a systematic overestimation of the FMH. For 8 out of 83 pregnant women, KBT was positive. Five were concordant with FCM results (KBT+/FCM+). On the three discordant (KBT+/FCM−), 2 were finally classified as false positive of the KBT because a second control sample was negative and additionally, FCM identified an increased rate of F cells. One discordant case (KBT+/FCM−) remained unexplained. By receiver operating characteristic analysis, we found a threshold at 4.5 RBCs for FCM with a sensitivity of 89.8% and a specificity of 93.2%. Conclusions: The FMH QuikQuant kit isAbstract: Background: The Kleihauer–Betke test (KBT) is the most widely used assay for fetomaternal hemorrhage (FMH) detection in rhesus D negative women. In the current study, we sought to evaluate the performance of a flow cytometry (FCM) kit (FMH QuikQuant) using an anti‐HbF antibody. Methods: Eighty‐three pregnant women, 58 umbilical cord blood (UCB) dilutions in adult blood, and 6 control samples were tested in parallel with FCM and KBT. Results: Firstly, we compared for each assay, on the 58 UCB preparations, results obtained to dilutions prepared. FCM results showed an excellent correlation ( r = 0.97), a high reproducibility with a coefficient of variation lower than 20% for values reaching 10 fetal RBCs. KBT values were correlated ( r = 0.94) but exhibited a poor reproducibility. Then, we compared both techniques on all samples. FCM showed a good correlation with KBT ( r = 0.87) but the KBT exhibited a systematic overestimation of the FMH. For 8 out of 83 pregnant women, KBT was positive. Five were concordant with FCM results (KBT+/FCM+). On the three discordant (KBT+/FCM−), 2 were finally classified as false positive of the KBT because a second control sample was negative and additionally, FCM identified an increased rate of F cells. One discordant case (KBT+/FCM−) remained unexplained. By receiver operating characteristic analysis, we found a threshold at 4.5 RBCs for FCM with a sensitivity of 89.8% and a specificity of 93.2%. Conclusions: The FMH QuikQuant kit is a reliable and highly reproductive FCM method for FMH quantification. © 2012 International Clinical Cytometry Society … (more)
- Is Part Of:
- Cytometry. Volume 84B:Issue 1(2013)
- Journal:
- Cytometry
- Issue:
- Volume 84B:Issue 1(2013)
- Issue Display:
- Volume 84, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 84
- Issue:
- 1
- Issue Sort Value:
- 2013-0084-0001-0000
- Page Start:
- 37
- Page End:
- 43
- Publication Date:
- 2012-10-26
- Subjects:
- flow cytometry -- fetomaternal hemorrhage -- F cells -- anti‐HbF antibody
Flow cytometry -- Diagnostic use -- Periodicals
Cytodiagnosis -- Periodicals
616.07582 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/cyto.b.21052 ↗
- Languages:
- English
- ISSNs:
- 1552-4949
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2855.xml