High‐intensity focused ultrasound treatment for skin: ex vivo evaluation. Issue 3 (20th November 2016)
- Record Type:
- Journal Article
- Title:
- High‐intensity focused ultrasound treatment for skin: ex vivo evaluation. Issue 3 (20th November 2016)
- Main Title:
- High‐intensity focused ultrasound treatment for skin: ex vivo evaluation
- Authors:
- Park, J.‐H.
Lim, S.‐D.
Oh, S. H.
Lee, J. H.
Yeo, U. C. - Abstract:
- Abstract : Background/Purpose: High‐intensity focused ultrasound (HIFU) has been used for skin tightening. However, there is a rising concern of irreversible adverse effects. Our aim was to evaluate the depth of thermal injury zone after HIFU energy passes through different condition. Materials and Methods: To analyze the consistency of the HIFU device, phantom tests were performed. Simulations were performed on ex vivo porcine tissues to estimate the area of the thermal coagulation point (TCP) according to the applied energy and skin condition. The experiment was designed in three orientations: normal direction (from epidermis to fascia), reverse direction (from fascia to epidermis), and normal direction without epidermis. Results: The TCP was larger and wider depending on the applied fluence and handpieces (HPs). When we measured TCP in different directions, the measured area in the normal direction was more superficially located than that in the reverse direction. The depth of the TCP in the porcine skin without epidermis was detected at 130% deeper than in skin with an intact epidermis. Conclusion: The affected area by HIFU is dependent on the skin condition and the characteristics of the HP and applied fluence. Considerations of these factors may be the key to minimize the unwanted adverse effects.
- Is Part Of:
- Skin research and technology. Volume 23:Issue 3(2017)
- Journal:
- Skin research and technology
- Issue:
- Volume 23:Issue 3(2017)
- Issue Display:
- Volume 23, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 23
- Issue:
- 3
- Issue Sort Value:
- 2017-0023-0003-0000
- Page Start:
- 384
- Page End:
- 391
- Publication Date:
- 2016-11-20
- Subjects:
- high‐intensity focused ultrasound -- treatment parameter -- skin condition -- porcine skin -- ex vivo experiment
Skin -- Research -- Periodicals
Skin -- Diseases -- Periodicals
Skin -- Physiology -- Periodicals
616.5 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0909-752X&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0846 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/srt.12347 ↗
- Languages:
- English
- ISSNs:
- 0909-752X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8295.948000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2818.xml