Variability in Stiffness Assessment in a Thyroid Nodule Using Shear Wave Imaging. Issue 4 (December 2015)
- Record Type:
- Journal Article
- Title:
- Variability in Stiffness Assessment in a Thyroid Nodule Using Shear Wave Imaging. Issue 4 (December 2015)
- Main Title:
- Variability in Stiffness Assessment in a Thyroid Nodule Using Shear Wave Imaging
- Authors:
- Brezak, Robert
Hippe, Dan
Thiel, Jeff
Dighe, Manjiri K. - Abstract:
- Abstract : Purpose: The aim of the study was to assess intrareader and interreader variability in placing a region of interest in the elastography color map in the thyroid nodule. Method and Materials: After institutional review board approval, elastograms were obtained by shear wave elastography from 38 individuals, with a total of 60 thyroid nodules. Two readers reviewed all images while blinded to the cytopathology or final histopathology results and to each other's measurements. For each image, readers first performed a qualitative assessment and recorded presence of stiff region(s) and number of stiff regions. Then, they placed a 3-mm circular region of interest on the stiffest region to quantify the mean and maximum stiffness in kilopascals. Intrareader and interreader agreement was summarized for categorical variables using Cohen κ and for continuous variables using the concordance correlation coefficient (CCC) and coefficient of variation. Results: There was good overall intrareader and interreader agreement for the presence of stiff regions and number of stiff regions after classifying them as 0, 1, and greater than 1 regions (κ = 0.78–0.81 and 0.74–0.79, respectively). There was also good overall agreement for the the following quantitative measurements: mean kPa (CCC = 0.97 and 0.93) and max kPa (CCC = 0.97 and 0.93). The intrareader and interreader coefficient of variation was 13% and 21% for mean kPa and 14% and 21% for max kPa. Conclusions: There can beAbstract : Purpose: The aim of the study was to assess intrareader and interreader variability in placing a region of interest in the elastography color map in the thyroid nodule. Method and Materials: After institutional review board approval, elastograms were obtained by shear wave elastography from 38 individuals, with a total of 60 thyroid nodules. Two readers reviewed all images while blinded to the cytopathology or final histopathology results and to each other's measurements. For each image, readers first performed a qualitative assessment and recorded presence of stiff region(s) and number of stiff regions. Then, they placed a 3-mm circular region of interest on the stiffest region to quantify the mean and maximum stiffness in kilopascals. Intrareader and interreader agreement was summarized for categorical variables using Cohen κ and for continuous variables using the concordance correlation coefficient (CCC) and coefficient of variation. Results: There was good overall intrareader and interreader agreement for the presence of stiff regions and number of stiff regions after classifying them as 0, 1, and greater than 1 regions (κ = 0.78–0.81 and 0.74–0.79, respectively). There was also good overall agreement for the the following quantitative measurements: mean kPa (CCC = 0.97 and 0.93) and max kPa (CCC = 0.97 and 0.93). The intrareader and interreader coefficient of variation was 13% and 21% for mean kPa and 14% and 21% for max kPa. Conclusions: There can be differences in measurement of stiffness by 2 different operators in softer nodules with shear wave imaging because of the lack of brighter areas on the color elastograms. A standardized technique is necessary to be able to compare results from 1 study to the next. … (more)
- Is Part Of:
- Ultrasound quarterly. Volume 31:Issue 4(2015)
- Journal:
- Ultrasound quarterly
- Issue:
- Volume 31:Issue 4(2015)
- Issue Display:
- Volume 31, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 31
- Issue:
- 4
- Issue Sort Value:
- 2015-0031-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-12
- Subjects:
- elastography -- thyroid -- shear wave imaging
Diagnostic ultrasonic imaging -- Periodicals
616.07543 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.8.1a/ovidweb.cgi?&S=PNMHFPHPLADDOHNFNCOKGBDCMNJGAA00&Full+Text=S.sh.18.19.24.25%7c408%7cFull+Text ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RUQ.0000000000000205 ↗
- Languages:
- English
- ISSNs:
- 0894-8771
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9082.815550
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2867.xml