Device optimised chirp stimulus for ABR measurements with an active middle ear implant. (3rd August 2017)
- Record Type:
- Journal Article
- Title:
- Device optimised chirp stimulus for ABR measurements with an active middle ear implant. (3rd August 2017)
- Main Title:
- Device optimised chirp stimulus for ABR measurements with an active middle ear implant
- Authors:
- Cebulla, Mario
Geiger, Ute
Hagen, Rudolf
Radeloff, Andreas - Abstract:
- Abstract: Objective : Active middle ear implants are widely used to treat adults and children with sensorineural, conductive, or mixed hearing loss. Currently, there is no adequate method to determine the performance of active middle ear implant systems. Design : The proposed method is based on measuring the auditory brainstem response while stimulating the hearing system via the active middle ear implant (Vibrant Soundbridge TM, VSB; MEDEL, Austria). The acoustic stimulation was achieved via an optimised chirp stimulus (CE-Chirp), implemented in the Eclipse system (Interacoustics, Denmark). To compensate for the frequency-specific delays in the VSB system, the underlying model function of the CE-Chirp was adjusted accordingly (VSB-CE-Chirp). Study samples : The study includes 12 subjects having mild to profound sensorineural, conductive or mixed hearing loss. Results : The use of an optimised VSB-CE-Chirp instead of the CE-Chirp increases significantly the ABR wave V amplitudes (1.63 times) and so also increases their identifiability (by 15.2%). On average, wave V could be identified at a 7.5 dB lower stimulation level. Conclusion : The constructed VSB-CE-Chirp stimulus, after it had been transmitted through the VSB system, follows well the shape of the original CE-Chirp. Preliminary measurements in VSB patients demonstrated a significantly improved ABR amplitude with the VSB-CE-Chirp.
- Is Part Of:
- International journal of audiology. Volume 56:Number 8(2017)
- Journal:
- International journal of audiology
- Issue:
- Volume 56:Number 8(2017)
- Issue Display:
- Volume 56, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 56
- Issue:
- 8
- Issue Sort Value:
- 2017-0056-0008-0000
- Page Start:
- 607
- Page End:
- 611
- Publication Date:
- 2017-08-03
- Subjects:
- Active middle ear implant -- ABR -- chirp stimulation -- ABR monitoring
Audiology -- Periodicals
Hearing disorders -- Periodicals
Deafness -- Prevention -- Periodicals
Hearing Disorders -- Periodicals
Hearing -- Periodicals
617.8 - Journal URLs:
- http://informahealthcare.com/loi/ija ↗
http://www.tandfonline.com/loi/iija20?open=54&repitition=0 ↗
http://informahealthcare.com ↗
http://journalsonline.tandf.co.uk/app/home/journal.asp?wasp=e54fd9ec35a8443595d2fe2a284d67dd&referrer=parent&backto=linkingpublicationresults, 1:112274, 1 ↗ - DOI:
- 10.1080/14992027.2017.1314558 ↗
- Languages:
- English
- ISSNs:
- 1499-2027
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.115000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2871.xml