Breast Mass Characterization Using 3‐Dimensional Automated Ultrasound as an Adjunct to Digital Breast Tomosynthesis: A Pilot Study. (1st January 2013)
- Record Type:
- Journal Article
- Title:
- Breast Mass Characterization Using 3‐Dimensional Automated Ultrasound as an Adjunct to Digital Breast Tomosynthesis: A Pilot Study. (1st January 2013)
- Main Title:
- Breast Mass Characterization Using 3‐Dimensional Automated Ultrasound as an Adjunct to Digital Breast Tomosynthesis
- Authors:
- Padilla, Frederic
Roubidoux, Marilyn A.
Paramagul, Chintana
Sinha, Sumedha P.
Goodsitt, Mitchell M.
Le Carpentier, Gerald L.
Chan, Heang-Ping
Hadjiiski, Lubomir M.
Fowlkes, J. Brian
Joe, Annette D.
Klein, Katherine A.
Nees, Alexis V.
Noroozian, Mitra
Patterson, Stephanie K.
Pinsky, Renee W.
Hooi, Fong Ming
Carson, Paul L. - Abstract:
- Abstract : Objectives: The purpose of this study was to retrospectively evaluate the effect of 3‐dimensional automated ultrasound (3D‐AUS) as an adjunct to digital breast tomosynthesis (DBT) on radiologists' performance and confidence in discriminating malignant and benign breast masses. Methods: Two‐view DBT (craniocaudal and mediolateral oblique or lateral) and single‐view 3D‐AUS images were acquired from 51 patients with subsequently biopsy‐proven masses (13 malignant and 38 benign). Six experienced radiologists rated, on a 13‐point scale, the likelihood of malignancy of an identified mass, first by reading the DBT images alone, followed immediately by reading the DBT images with automatically coregistered 3D‐AUS images. The diagnostic performance of each method was measured using receiver operating characteristic (ROC) curve analysis and changes in sensitivity and specificity with the McNemar test. After each reading, radiologists took a survey to rate their confidence level in using DBT alone versus combined DBT/3D‐AUS as potential screening modalities. Results: The 6 radiologists had an average area under the ROC curve of 0.92 for both modalities (range, 0.89–0.97 for DBT and 0.90–0.94 for DBT/3D‐AUS). With a Breast Imaging Reporting and Data System rating of 4 as the threshold for biopsy recommendation, the average sensitivity of the radiologists increased from 96% to 100% ( P > .08) with 3D‐AUS, whereas the specificity decreased from 33% to 25% ( P > .28). SurveyAbstract : Objectives: The purpose of this study was to retrospectively evaluate the effect of 3‐dimensional automated ultrasound (3D‐AUS) as an adjunct to digital breast tomosynthesis (DBT) on radiologists' performance and confidence in discriminating malignant and benign breast masses. Methods: Two‐view DBT (craniocaudal and mediolateral oblique or lateral) and single‐view 3D‐AUS images were acquired from 51 patients with subsequently biopsy‐proven masses (13 malignant and 38 benign). Six experienced radiologists rated, on a 13‐point scale, the likelihood of malignancy of an identified mass, first by reading the DBT images alone, followed immediately by reading the DBT images with automatically coregistered 3D‐AUS images. The diagnostic performance of each method was measured using receiver operating characteristic (ROC) curve analysis and changes in sensitivity and specificity with the McNemar test. After each reading, radiologists took a survey to rate their confidence level in using DBT alone versus combined DBT/3D‐AUS as potential screening modalities. Results: The 6 radiologists had an average area under the ROC curve of 0.92 for both modalities (range, 0.89–0.97 for DBT and 0.90–0.94 for DBT/3D‐AUS). With a Breast Imaging Reporting and Data System rating of 4 as the threshold for biopsy recommendation, the average sensitivity of the radiologists increased from 96% to 100% ( P > .08) with 3D‐AUS, whereas the specificity decreased from 33% to 25% ( P > .28). Survey responses indicated increased confidence in potentially using DBT for screening when 3D‐AUS was added ( P < .05 for each reader). Conclusions: In this initial reader study, no significant difference in ROC performance was found with the addition of 3D‐AUS to DBT. However, a trend to improved discrimination of malignancy was observed when adding 3D‐AUS. Radiologists' confidence also improved with DBT/3DAUS compared to DBT alone. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 32:Number 1(2013)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 32:Number 1(2013)
- Issue Display:
- Volume 32, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 32
- Issue:
- 1
- Issue Sort Value:
- 2013-0032-0001-0000
- Page Start:
- 93
- Page End:
- 104
- Publication Date:
- 2013-01-01
- Subjects:
- automated ultrasound -- breast -- reader study -- tomosynthesis
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.7863/jum.2013.32.1.93 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2806.xml