Automatic multimodal detection for long-term seizure documentation in epilepsy. Issue 8 (August 2017)
- Record Type:
- Journal Article
- Title:
- Automatic multimodal detection for long-term seizure documentation in epilepsy. Issue 8 (August 2017)
- Main Title:
- Automatic multimodal detection for long-term seizure documentation in epilepsy
- Authors:
- Fürbass, F.
Kampusch, S.
Kaniusas, E.
Koren, J.
Pirker, S.
Hopfengärtner, R.
Stefan, H.
Kluge, T.
Baumgartner, C. - Abstract:
- Highlights: Automatic seizure detection assessing efficacy of EEG/ECG/EMG signals for seizure documentation. Multi-center evaluation including 92 patients with 494 seizures comparing full to reduced montages. Using 8 frontal and temporal electrodes will significantly improve conventional seizure reporting. Abstract: Objective: This study investigated sensitivity and false detection rate of a multimodal automatic seizure detection algorithm and the applicability to reduced electrode montages for long-term seizure documentation in epilepsy patients. Methods: An automatic seizure detection algorithm based on EEG, EMG, and ECG signals was developed. EEG/ECG recordings of 92 patients from two epilepsy monitoring units including 494 seizures were used to assess detection performance. EMG data were extracted by bandpass filtering of EEG signals. Sensitivity and false detection rate were evaluated for each signal modality and for reduced electrode montages. Results: All focal seizures evolving to bilateral tonic-clonic (BTCS, n = 50) and 89% of focal seizures (FS, n = 139) were detected. Average sensitivity in temporal lobe epilepsy (TLE) patients was 94% and 74% in extratemporal lobe epilepsy (XTLE) patients. Overall detection sensitivity was 86%. Average false detection rate was 12.8 false detections in 24 h (FD/24 h) for TLE and 22 FD/24 h in XTLE patients. Utilization of 8 frontal and temporal electrodes reduced average sensitivity from 86% to 81%. Conclusion: Our automaticHighlights: Automatic seizure detection assessing efficacy of EEG/ECG/EMG signals for seizure documentation. Multi-center evaluation including 92 patients with 494 seizures comparing full to reduced montages. Using 8 frontal and temporal electrodes will significantly improve conventional seizure reporting. Abstract: Objective: This study investigated sensitivity and false detection rate of a multimodal automatic seizure detection algorithm and the applicability to reduced electrode montages for long-term seizure documentation in epilepsy patients. Methods: An automatic seizure detection algorithm based on EEG, EMG, and ECG signals was developed. EEG/ECG recordings of 92 patients from two epilepsy monitoring units including 494 seizures were used to assess detection performance. EMG data were extracted by bandpass filtering of EEG signals. Sensitivity and false detection rate were evaluated for each signal modality and for reduced electrode montages. Results: All focal seizures evolving to bilateral tonic-clonic (BTCS, n = 50) and 89% of focal seizures (FS, n = 139) were detected. Average sensitivity in temporal lobe epilepsy (TLE) patients was 94% and 74% in extratemporal lobe epilepsy (XTLE) patients. Overall detection sensitivity was 86%. Average false detection rate was 12.8 false detections in 24 h (FD/24 h) for TLE and 22 FD/24 h in XTLE patients. Utilization of 8 frontal and temporal electrodes reduced average sensitivity from 86% to 81%. Conclusion: Our automatic multimodal seizure detection algorithm shows high sensitivity with full and reduced electrode montages. Significance: Evaluation of different signal modalities and electrode montages paces the way for semi-automatic seizure documentation systems. … (more)
- Is Part Of:
- Clinical neurophysiology. Volume 128:Issue 8(2017:Aug.)
- Journal:
- Clinical neurophysiology
- Issue:
- Volume 128:Issue 8(2017:Aug.)
- Issue Display:
- Volume 128, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 128
- Issue:
- 8
- Issue Sort Value:
- 2017-0128-0008-0000
- Page Start:
- 1466
- Page End:
- 1472
- Publication Date:
- 2017-08
- Subjects:
- Multimodal -- Automatic -- Seizure detection -- Algorithm -- ECG -- EMG -- EEG
Neurophysiology -- Periodicals
Electroencephalography -- Periodicals
Electromyography -- Periodicals
Neurology -- Periodicals
612.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13882457 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinph.2017.05.013 ↗
- Languages:
- English
- ISSNs:
- 1388-2457
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.310645
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2876.xml