Wesołowska, Maria - Abstract:
- Abstract: Heat and humidity processes occurring in external wall of heated buildings depend mostly on external climate factors, i.e. air temperature and relative humidity, rainfall, sun radiation and conditions inside rooms. In three layer walls the face layer is specially endangered as humidity together with negative temperatures contribute to lowering its durability. Increased humidity content results in lowering insulating properties of materials which in turn leads to increasing heat consumption in a building during the heating period. In the article there are introduced results of simulations performed with WUFI ®PRO 5 software which aimed at analysing the face layer humidity changes caused by: exploitation conditions defined by 3rd and 4th class of room internal humidity, external climate influence, partition orientation. The calculation were performed for two different internal partitions drying from technological humidity during the initial five years of building exploitation. The partition in question is a three layer wall with pore ceramic 25 cm thick and elevation layer of clinker brick 12 cm thick. In the first variant insulation is mineral wool, in the second - styrofoam. For the particular layers of analysed partitions initial humidity content was assumed as resulting from technological conditions for building walls. The simulation let us state the technological humidity drying period of face layer, as well as humidity changes during the later period ofAbstract: Heat and humidity processes occurring in external wall of heated buildings depend mostly on external climate factors, i.e. air temperature and relative humidity, rainfall, sun radiation and conditions inside rooms. In three layer walls the face layer is specially endangered as humidity together with negative temperatures contribute to lowering its durability. Increased humidity content results in lowering insulating properties of materials which in turn leads to increasing heat consumption in a building during the heating period. In the article there are introduced results of simulations performed with WUFI ®PRO 5 software which aimed at analysing the face layer humidity changes caused by: exploitation conditions defined by 3rd and 4th class of room internal humidity, external climate influence, partition orientation. The calculation were performed for two different internal partitions drying from technological humidity during the initial five years of building exploitation. The partition in question is a three layer wall with pore ceramic 25 cm thick and elevation layer of clinker brick 12 cm thick. In the first variant insulation is mineral wool, in the second - styrofoam. For the particular layers of analysed partitions initial humidity content was assumed as resulting from technological conditions for building walls. The simulation let us state the technological humidity drying period of face layer, as well as humidity changes during the later period of exploitation resulting from climate influence. It was stated that elevation layer humidity condition is strictly associated with applied thermo-insulating material and partition orientation according geographic directions. … (more)
- Is Part Of:
- Procedia engineering. Volume 193(2017)
- Journal:
- Procedia engineering
- Issue:
- Volume 193(2017)
- Issue Display:
- Volume 193, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 193
- Issue:
- 2017
- Issue Sort Value:
- 2017-0193-2017-0000
- Page Start:
- 205
- Page End:
- 210
- Publication Date:
- 2017
- Subjects:
- external wall -- impact of climate -- simulation analysis
Engineering -- Congresses
Engineering -- Periodicals
Engineering
Conference proceedings
Periodicals
620.005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18777058 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.proeng.2017.06.205 ↗
- Languages:
- English
- ISSNs:
- 1877-7058
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2821.xml