Comparison of Amicus and COBE Spectra for allogenic peripheral blood stem cell harvest: Study from tertiary care centre in India. Issue 3 (June 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of Amicus and COBE Spectra for allogenic peripheral blood stem cell harvest: Study from tertiary care centre in India. Issue 3 (June 2017)
- Main Title:
- Comparison of Amicus and COBE Spectra for allogenic peripheral blood stem cell harvest: Study from tertiary care centre in India
- Authors:
- Setia, Rasika Dhawan
Arora, Satyam
Handoo, Anil
Dadu, Tina
Choudhary, Dharma
Sharma, Sajeev Kumar
Kharya, Gaurav
Khandelwal, Vipin
Sachdeva, Prerna
Doval, Divya
Bakliwal, Anamika
Kapoor, Meenu
Bajaj, Shalu
Bachchas, Virendra
Singh, Praveen - Abstract:
- Abstract: Introduction: Most common source of stem cell graft for both autologous and allogenic haematopoietic transplants are peripheral blood haematopoietic progenitor stem cells. Adequate collection of the CD34+ cells and safety of the allogenic donor during the leukapheresis are of prime importance to an apheresis physician. Our retrospective analysis is a comparison between of two platforms namely, COBE Spectra and Amicus, for CD34+ mononuclear cell collection. Material and method: The study included the data of GSCF (Granulocyte-Colony-Stimulating Factor) mobilized allogenic PBSC collections at our centre from January 2015 to June 2016. The apheresis platforms used were COBE Spectra and Amicus. Blood cell counts were done using LH750 Beckman Coulter (Florida, Miami, USA). CD45+ & CD34+ cell counts were done using BD FACS Canto-II Flow-Cytometer by ISHAGE guidelines. Results: A total of 170 PBSC (100 COBE Spectra & 70 Amicus) harvests were done on 143 donors, of which 116 completed the collection in a single session and 27 required a second session. Demographic details and pre harvest peripheral blood counts for both the groups did not show any statistical differences. Amicus processed higher blood volume with higher ACD exposure and procedure time compared to COBE Spectra. Higher platelets loss was with COBE Spectra harvests with higher product volumes collection. Collection efficiency (CE2), collection ratio, CD34+ cells dose was similar on both the platforms. RBCAbstract: Introduction: Most common source of stem cell graft for both autologous and allogenic haematopoietic transplants are peripheral blood haematopoietic progenitor stem cells. Adequate collection of the CD34+ cells and safety of the allogenic donor during the leukapheresis are of prime importance to an apheresis physician. Our retrospective analysis is a comparison between of two platforms namely, COBE Spectra and Amicus, for CD34+ mononuclear cell collection. Material and method: The study included the data of GSCF (Granulocyte-Colony-Stimulating Factor) mobilized allogenic PBSC collections at our centre from January 2015 to June 2016. The apheresis platforms used were COBE Spectra and Amicus. Blood cell counts were done using LH750 Beckman Coulter (Florida, Miami, USA). CD45+ & CD34+ cell counts were done using BD FACS Canto-II Flow-Cytometer by ISHAGE guidelines. Results: A total of 170 PBSC (100 COBE Spectra & 70 Amicus) harvests were done on 143 donors, of which 116 completed the collection in a single session and 27 required a second session. Demographic details and pre harvest peripheral blood counts for both the groups did not show any statistical differences. Amicus processed higher blood volume with higher ACD exposure and procedure time compared to COBE Spectra. Higher platelets loss was with COBE Spectra harvests with higher product volumes collection. Collection efficiency (CE2), collection ratio, CD34+ cells dose was similar on both the platforms. RBC contamination, absolute lymphocyte and monocytes counts were significantly higher with Amicus harvest product compared with COBE Spectra. A total of 14 (8.2%; citrate toxicity) adverse reactions were reported out of 170 allogenic PBSC collections. Discussion/conclusion: Our study suggests that both Amicus and COBE Spectra platforms offer comparable results for allogenic PBSC collections. Amicus offers a concentrated PBSC product with lesser volume and platelets loss but higher RBC contamination. … (more)
- Is Part Of:
- Transfusion and apheresis science. Volume 56:Issue 3(2017)
- Journal:
- Transfusion and apheresis science
- Issue:
- Volume 56:Issue 3(2017)
- Issue Display:
- Volume 56, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 56
- Issue:
- 3
- Issue Sort Value:
- 2017-0056-0003-0000
- Page Start:
- 439
- Page End:
- 444
- Publication Date:
- 2017-06
- Subjects:
- Peripheral blood stem cells -- Amicus -- COBE Spectra -- CD34+ dose -- Collection efficiency
Blood -- Transfusion -- Periodicals
Hemapheresis -- Periodicals
615.39 - Journal URLs:
- http://www.sciencedirect.com/science/journal/14730502 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/14730502 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/14730502 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.transci.2017.04.002 ↗
- Languages:
- English
- ISSNs:
- 1473-0502
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2878.xml