Epileptiform discharge detection with the 4-channel frontal electroencephalography during post-resuscitation care. (August 2017)
- Record Type:
- Journal Article
- Title:
- Epileptiform discharge detection with the 4-channel frontal electroencephalography during post-resuscitation care. (August 2017)
- Main Title:
- Epileptiform discharge detection with the 4-channel frontal electroencephalography during post-resuscitation care
- Authors:
- You, Kyoung Min
Suh, Gil Joon
Kwon, Woon Yong
Kim, Kyung Su
Ko, Sang-Bae
Park, Min Ji
Kim, Taegyun
Ko, Jung-In - Abstract:
- Abstract: Introduction: We performed this study to investigate whether the SEDline system, a 4-channel-processed electroencephalography (EEG) monitoring device in the frontal area, can detect epileptiform discharges accurately during post-resuscitation care in comatose cardiac arrest survivors. Methods: Adult comatose cardiac arrest survivors, who were admitted to the intensive care unit (ICU) for post-resuscitation care including TTM, were enrolled. Within 72 h post-return of spontaneous circulation (ROSC), conventional EEG was conducted for 30 min. The SEDline system data were recorded with a video camera simultaneously with conventional EEG. Data retrieved from conventional EEG were interpreted by a neurologist and data from the SEDline system were interpreted by three emergency physicians blinded to the conventional EEG data. Then, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the SEDline system to detect epileptiform discharges were calculated. Results: Thirty-nine patients were enrolled in this study. Epileptiform discharges were confirmed in 6 patients (15.4%) who had the same patterns of generalized periodic epileptiform discharges in both conventional EEG and the concurrent SEDline system. The SEDline system showed 100.0% (95% confidence interval (CI), 54.1–100.0%) of sensitivity, 100.0% (95% CI, 89.4–100.0%) of specificity, 100.0% (95% CI, 54.1–100.0%) of PPV, and 100.0% (95% CI, 89.4–100.0%) of NPV.Abstract: Introduction: We performed this study to investigate whether the SEDline system, a 4-channel-processed electroencephalography (EEG) monitoring device in the frontal area, can detect epileptiform discharges accurately during post-resuscitation care in comatose cardiac arrest survivors. Methods: Adult comatose cardiac arrest survivors, who were admitted to the intensive care unit (ICU) for post-resuscitation care including TTM, were enrolled. Within 72 h post-return of spontaneous circulation (ROSC), conventional EEG was conducted for 30 min. The SEDline system data were recorded with a video camera simultaneously with conventional EEG. Data retrieved from conventional EEG were interpreted by a neurologist and data from the SEDline system were interpreted by three emergency physicians blinded to the conventional EEG data. Then, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the SEDline system to detect epileptiform discharges were calculated. Results: Thirty-nine patients were enrolled in this study. Epileptiform discharges were confirmed in 6 patients (15.4%) who had the same patterns of generalized periodic epileptiform discharges in both conventional EEG and the concurrent SEDline system. The SEDline system showed 100.0% (95% confidence interval (CI), 54.1–100.0%) of sensitivity, 100.0% (95% CI, 89.4–100.0%) of specificity, 100.0% (95% CI, 54.1–100.0%) of PPV, and 100.0% (95% CI, 89.4–100.0%) of NPV. The overall classification accuracy of the SEDline system to detect epileptiform discharges was 100.0%. Conclusion: The SEDline system detected epileptiform discharges accurately in comatose cardiac arrest survivors during post-resuscitation care. … (more)
- Is Part Of:
- Resuscitation. Volume 117(2017)
- Journal:
- Resuscitation
- Issue:
- Volume 117(2017)
- Issue Display:
- Volume 117, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 117
- Issue:
- 2017
- Issue Sort Value:
- 2017-0117-2017-0000
- Page Start:
- 8
- Page End:
- 13
- Publication Date:
- 2017-08
- Subjects:
- Heart arrest -- Cardiopulmonary resuscitation -- Electroencephalography -- Seizures
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2017.05.016 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2819.xml