Effect of diffusible hydrogen content on embrittlement of P92 steel. (6th July 2017)
- Record Type:
- Journal Article
- Title:
- Effect of diffusible hydrogen content on embrittlement of P92 steel. (6th July 2017)
- Main Title:
- Effect of diffusible hydrogen content on embrittlement of P92 steel
- Authors:
- Saini, Nitin
Pandey, Chandan
Mahapatra, Manas Mohan - Abstract:
- Abstract: In the present investigation, varying electrode conditions (dried and contaminated) have been employed during welding of P92 steel to study the effect of diffusible hydrogen level on hydrogen-assisted cracking (HAC). Shielded metal arc welding process was employed to deposit the metal on a P92 steel plate. To evaluate HAC, the Granjon implant test with varying diffusible hydrogen content in the deposited metal was utilized. The diffusible hydrogen level was measured in the deposited metal by using the mercury method. Lower critical stress (LCS), embrittlement index (EI) and normalized critical stress ratio were evaluated from the Granjon implant test. The fracture surface morphology of fractured implant specimens has been studied by using a field emission secondary electron microscope. The P92 steel plate welded by the contaminated electrode with a high level of diffusible hydrogen was found to be more susceptible to HAC. As diffusible hydrogen content increased in the deposited metal, the LCS value and EI were observed to be decreased. Graphical abstract: Highlights: Diffusible hydrogen measurement of SMAW P92 deposits for varying condition of electrode. Measurement of lower critical stress for P92 steel. Effect of diffusible hydrogen on embrittlement index, critical stress ratio and lower critical stress. Effect of diffusible hydrogen on microstructure evolution of P92 weldments. Effect of varying diffusible hydrogen content on fracture morphology of implantAbstract: In the present investigation, varying electrode conditions (dried and contaminated) have been employed during welding of P92 steel to study the effect of diffusible hydrogen level on hydrogen-assisted cracking (HAC). Shielded metal arc welding process was employed to deposit the metal on a P92 steel plate. To evaluate HAC, the Granjon implant test with varying diffusible hydrogen content in the deposited metal was utilized. The diffusible hydrogen level was measured in the deposited metal by using the mercury method. Lower critical stress (LCS), embrittlement index (EI) and normalized critical stress ratio were evaluated from the Granjon implant test. The fracture surface morphology of fractured implant specimens has been studied by using a field emission secondary electron microscope. The P92 steel plate welded by the contaminated electrode with a high level of diffusible hydrogen was found to be more susceptible to HAC. As diffusible hydrogen content increased in the deposited metal, the LCS value and EI were observed to be decreased. Graphical abstract: Highlights: Diffusible hydrogen measurement of SMAW P92 deposits for varying condition of electrode. Measurement of lower critical stress for P92 steel. Effect of diffusible hydrogen on embrittlement index, critical stress ratio and lower critical stress. Effect of diffusible hydrogen on microstructure evolution of P92 weldments. Effect of varying diffusible hydrogen content on fracture morphology of implant specimen. … (more)
- Is Part Of:
- International journal of hydrogen energy. Volume 42:Number 27(2017)
- Journal:
- International journal of hydrogen energy
- Issue:
- Volume 42:Number 27(2017)
- Issue Display:
- Volume 42, Issue 27 (2017)
- Year:
- 2017
- Volume:
- 42
- Issue:
- 27
- Issue Sort Value:
- 2017-0042-0027-0000
- Page Start:
- 17328
- Page End:
- 17338
- Publication Date:
- 2017-07-06
- Subjects:
- Implant test -- Diffusible hydrogen -- Lower critical stress -- P92 steel -- Hydrogen assisted cracking -- Heat affected zone
Hydrogen as fuel -- Periodicals
Hydrogène (Combustible) -- Périodiques
Hydrogen as fuel
Periodicals
665.81 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03603199 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijhydene.2017.05.214 ↗
- Languages:
- English
- ISSNs:
- 0360-3199
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.290000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2784.xml