Patient doses and occupational exposure in a hybrid operating room. (May 2017)
- Record Type:
- Journal Article
- Title:
- Patient doses and occupational exposure in a hybrid operating room. (May 2017)
- Main Title:
- Patient doses and occupational exposure in a hybrid operating room
- Authors:
- Andrés, C.
Pérez-García, H.
Agulla, M.
Torres, R.
Miguel, D.
del Castillo, A.
Flota, C.M.
Alonso, D.
de Frutos, J.
Vaquero, C. - Abstract:
- Highlights: The radiation protection carried out in the first year of use of an HOR dedicated to vascular surgery was evaluated. Working conditions in the HOR are safe regarding patient and staff radiation protection. Patient doses are comparable to those resulting from other endovascular dose studies. Annual dose limit to the exposed professionals were not exceeded during the study. Abstract: Purpose: This study aimed to characterize the radiation exposure to patients and workers in a new vascular hybrid operating room during X-ray-guided procedures. Methods: During one year, data from 260 interventions performed in a hybrid operating room equipped with a Siemens Artis Zeego angiography system were monitored. The patient doses were analysed using the following parameters: radiation time, kerma-area product, patient entrance reference point dose and peak skin dose. Staff radiation exposure and ambient dose equivalent were also measured using direct reading dosimeters and thermoluminescent dosimeters. Results: The radiation time, kerma-area product, patient entrance reference point dose and peak skin dose were, on average, 19:15 min, 67 Gy·cm 2, 0.41 Gy and 0.23 Gy, respectively. Although the contribution of the acquisition mode was smaller than 5% in terms of the radiation time, this mode accounted for more than 60% of the effective dose per patient. All of the worker dose measurements remained below the limits established by law. Conclusions: The working conditions in theHighlights: The radiation protection carried out in the first year of use of an HOR dedicated to vascular surgery was evaluated. Working conditions in the HOR are safe regarding patient and staff radiation protection. Patient doses are comparable to those resulting from other endovascular dose studies. Annual dose limit to the exposed professionals were not exceeded during the study. Abstract: Purpose: This study aimed to characterize the radiation exposure to patients and workers in a new vascular hybrid operating room during X-ray-guided procedures. Methods: During one year, data from 260 interventions performed in a hybrid operating room equipped with a Siemens Artis Zeego angiography system were monitored. The patient doses were analysed using the following parameters: radiation time, kerma-area product, patient entrance reference point dose and peak skin dose. Staff radiation exposure and ambient dose equivalent were also measured using direct reading dosimeters and thermoluminescent dosimeters. Results: The radiation time, kerma-area product, patient entrance reference point dose and peak skin dose were, on average, 19:15 min, 67 Gy·cm 2, 0.41 Gy and 0.23 Gy, respectively. Although the contribution of the acquisition mode was smaller than 5% in terms of the radiation time, this mode accounted for more than 60% of the effective dose per patient. All of the worker dose measurements remained below the limits established by law. Conclusions: The working conditions in the hybrid operating room HOR are safe in terms of patient and staff radiation protection. Nevertheless, doses are highly dependent on the workload; thus, further research is necessary to evaluate any possible radiological deviation of the daily working conditions in the HOR. … (more)
- Is Part Of:
- Physica medica. Volume 37(2017)
- Journal:
- Physica medica
- Issue:
- Volume 37(2017)
- Issue Display:
- Volume 37, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 37
- Issue:
- 2017
- Issue Sort Value:
- 2017-0037-2017-0000
- Page Start:
- 37
- Page End:
- 42
- Publication Date:
- 2017-05
- Subjects:
- Hybrid operating room -- Artis Zeego -- Patient dose -- Occupational exposure
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2017.04.006 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 775.xml