Comparison of DCE‐MRI kinetic parameters and FMISO‐PET uptake parameters in head and neck cancer patients. Issue 6 (20th April 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of DCE‐MRI kinetic parameters and FMISO‐PET uptake parameters in head and neck cancer patients. Issue 6 (20th April 2017)
- Main Title:
- Comparison of DCE‐MRI kinetic parameters and FMISO‐PET uptake parameters in head and neck cancer patients
- Authors:
- Simoncic, Urban
Leibfarth, Sara
Welz, Stefan
Schwenzer, Nina
Schmidt, Holger
Reischl, Gerald
Pfannenberg, Christina
Fougère, Christian la
Nikolaou, Konstantin
Zips, Daniel
Thorwarth, Daniela - Abstract:
- Abstract : Purpose: Tumor hypoxia is a major cause of radiation resistance, often present in various solid tumors. Dynamic [ 18 F]‐fluoromisonidazole (FMISO) PET imaging is able to reliably assess tumor hypoxia. Comprehensive characterization of tumor microenvironment through FMISO‐PET and dynamic contrast enhanced (DCE) MR multimodality imaging might be a valuable alternative to the dynamic FMISO‐PET acquisition. The aim of this work was to explore the correlation between the FMISO‐PET and DCE‐MRI kinetic parameters. Methods: This study was done on head and neck cancer patients (N = 6), who were imaged dynamically with FMISO‐PET and DCE‐MRI on the same day. Images were registered and analyzed for kinetics on a voxel basis. FMISO‐PET images were analyzed with the two‐tissue compartment three rate‐constant model. Additionally, tumor‐to‐muscle ratio (TMR) maps were evaluated. DCE‐MRI was analyzed with the extended Tofts model. Voxel‐wise Pearson's coefficients were calculated for each patient to assess pairwise parameter correlations. Results: Median correlations between FMISO uptake parameters and DCE‐MRI kinetic parameters varied across the parameter pairs in the range from −0.05 to 0.71. The highest median correlation of r = 0.71 was observed for the pair V b − v p, while the K 1 − K trans median correlation was r = 0.45. Median correlation coefficients for the K 1 − v p and the K i − K trans pairs were r = 0.42 and r = 0.32, respectively. Correlations between FMISO uptakeAbstract : Purpose: Tumor hypoxia is a major cause of radiation resistance, often present in various solid tumors. Dynamic [ 18 F]‐fluoromisonidazole (FMISO) PET imaging is able to reliably assess tumor hypoxia. Comprehensive characterization of tumor microenvironment through FMISO‐PET and dynamic contrast enhanced (DCE) MR multimodality imaging might be a valuable alternative to the dynamic FMISO‐PET acquisition. The aim of this work was to explore the correlation between the FMISO‐PET and DCE‐MRI kinetic parameters. Methods: This study was done on head and neck cancer patients (N = 6), who were imaged dynamically with FMISO‐PET and DCE‐MRI on the same day. Images were registered and analyzed for kinetics on a voxel basis. FMISO‐PET images were analyzed with the two‐tissue compartment three rate‐constant model. Additionally, tumor‐to‐muscle ratio (TMR) maps were evaluated. DCE‐MRI was analyzed with the extended Tofts model. Voxel‐wise Pearson's coefficients were calculated for each patient to assess pairwise parameter correlations. Results: Median correlations between FMISO uptake parameters and DCE‐MRI kinetic parameters varied across the parameter pairs in the range from −0.05 to 0.71. The highest median correlation of r = 0.71 was observed for the pair V b − v p, while the K 1 − K trans median correlation was r = 0.45. Median correlation coefficients for the K 1 − v p and the K i − K trans pairs were r = 0.42 and r = 0.32, respectively. Correlations between FMISO uptake rate parameter K i and DCE‐MRI kinetic parameters varied substantially across the patients, whereas correlations between the FMISO and DCE‐MRI vascular parameters were consistently high. Median TMR‐ K 1 and TMR‐ K trans correlations were r = 0.52 and r = 0.46, respectively, but varied substantially across the patients. Conclusions: Based on this clinical evidence, we can conclude that the vascular fraction parameters obtained through DCE‐MRI kinetic analysis or FMISO kinetic analysis measure the same biological property, while other kinetic parameters are unrelated. These results might be useful in the design of future clinical trials involving FMISO‐PET/DCE‐MR multimodality imaging for the assessment of tumor microenvironment. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 6(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 6(2017)
- Issue Display:
- Volume 44, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 6
- Issue Sort Value:
- 2017-0044-0006-0000
- Page Start:
- 2358
- Page End:
- 2368
- Publication Date:
- 2017-04-20
- Subjects:
- DCE‐MRI -- FMISO -- hypoxia -- image quantification -- kinetic analysis -- PET -- vascular kinetic parameters
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12228 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2810.xml