Intra-operative reliability of ShapeMatch cutting guide placement in total knee arthroplasty*. (5th March 2013)
- Record Type:
- Journal Article
- Title:
- Intra-operative reliability of ShapeMatch cutting guide placement in total knee arthroplasty*. (5th March 2013)
- Main Title:
- Intra-operative reliability of ShapeMatch cutting guide placement in total knee arthroplasty*
- Authors:
- Clark, Gavin
Leong, Anthony
McEwen, Peter
Steele, Robert
Tran, Ton
Trivett, Adrian - Abstract:
- Abstract : Custom cutting guides based on pre-operative imaging have been introduced for total knee arthroplasty (TKA). The aim of this prospective cohort study was to assess the reliability of repeated placement of custom cutting guides by multiple surgeons in a group of patients undergoing TKA. Custom cutting guides (ShapeMatch®, Stryker Orthopaedics) were designed from pre-operative MRI scans. The treating surgeon placed each guide on the femur and tibia of each patient three times without pinning the block. The three-dimensional position and orientation of the guide was measured for each repetition using a computer navigation system. The surgeon was blinded to the navigation system display. Data from 24 patients and 6 surgeons were analyzed. Intraclass correlation coefficients for all measurement parameters were in the range 0.889–0.997 (excellent), and all comparisons were statistically significant ( p < 0.001). The range for femoral varus/valgus was 0.0–1.5°, with 96% of patients being within 0.5°. For femoral flexion/extension the range was 0.0–3.5° (92% within 2.5°). On the tibia, varus/valgus had a range of 0.0–1.0° (92% within 0.5°), and for slope the range was 0.0–3.5° (92% within 2.5°). The high degree of agreement indicated that intra-surgeon variation was minimal and that the technique is reliable.
- Is Part Of:
- Computer aided surgery. Volume 18:Number 5/6(2013:Sep./Nov.)
- Journal:
- Computer aided surgery
- Issue:
- Volume 18:Number 5/6(2013:Sep./Nov.)
- Issue Display:
- Volume 18, Issue 5/6 (2013)
- Year:
- 2013
- Volume:
- 18
- Issue:
- 5/6
- Issue Sort Value:
- 2013-0018-NaN-0000
- Page Start:
- 159
- Page End:
- 165
- Publication Date:
- 2013-03-05
- Subjects:
- Total knee arthropasty -- custom-fit cutting guide -- reproducibility -- computer-assisted surgery
Computer-assisted surgery -- Periodicals
Imaging systems in medicine -- Periodicals
Surgery, Operative -- Computer simulation -- Periodicals
Surgical technology -- Periodicals
Medical technology -- Periodicals
617.90285 - Journal URLs:
- http://informahealthcare.com/loi/csu ↗
http://www3.interscience.wiley.com/cgi-bin/jtoc?ID=56867 ↗
http://informahealthcare.com ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.3109/10929088.2013.774049 ↗
- Languages:
- English
- ISSNs:
- 1092-9088
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3393.542410
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2787.xml