Utility of newly developed short‐type double‐balloon endoscopy for endoscopic retrograde cholangiography in postoperative patients. Issue 7 (22nd June 2017)
- Record Type:
- Journal Article
- Title:
- Utility of newly developed short‐type double‐balloon endoscopy for endoscopic retrograde cholangiography in postoperative patients. Issue 7 (22nd June 2017)
- Main Title:
- Utility of newly developed short‐type double‐balloon endoscopy for endoscopic retrograde cholangiography in postoperative patients
- Authors:
- Shimatani, Masaaki
Tokuhara, Mitsuo
Kato, Kota
Miyamoto, Sachi
Masuda, Masataka
Sakao, Masayuki
Fukata, Norimasa
Miyoshi, Hideaki
Ikeura, Tsukasa
Takaoka, Makoto
Okazaki, Kazuichi - Abstract:
- Abstract: Background and Aim: The utility of conventional short‐type double‐balloon endoscopy (DBE) for pancreatobiliary disease in patients with postoperative anatomy had been widely acknowledged and accepted. However, some technical difficulties yet remained. In an attempt to solve these problems, the new short‐type DBE (N‐short DBE) was uniquely designed for therapeutic endoscopic retrograde cholangiography (ERC) in postoperative patients. The aim of this study was to evaluate the usefulness of N‐short DBE for ERC in postoperative patients. Methods: From August 2015 to April 2016, ERC using N‐short DBE (DB‐ERC) was performed in 100 postoperative patients (112 procedures). We retrospectively studied the success rate of reaching the blind end, the median time to reach the blind end, the diagnostic success rate, the therapeutic success rate, the median time to complete ERC‐related interventions, the overall success rate, the median time to complete DB‐ERC, and adverse events. Results: The success rate of reaching the blind end was 99.1%. The median time to reach the blind end was 10 min (interquartile range [IQR], 6–19 min). The diagnostic success rate was 98.2%. The therapeutic success rate was 100%. The median time to complete ERC‐related interventions was 36 min (IQR, 22–62 min). The overall DB‐ERC success rate was 97.3%. The median time to complete DB‐ERC was 54 min (IQR, 37–73 min). The occurrence of adverse events was 2.7%. Conclusions: The N‐short DBE for ERC inAbstract: Background and Aim: The utility of conventional short‐type double‐balloon endoscopy (DBE) for pancreatobiliary disease in patients with postoperative anatomy had been widely acknowledged and accepted. However, some technical difficulties yet remained. In an attempt to solve these problems, the new short‐type DBE (N‐short DBE) was uniquely designed for therapeutic endoscopic retrograde cholangiography (ERC) in postoperative patients. The aim of this study was to evaluate the usefulness of N‐short DBE for ERC in postoperative patients. Methods: From August 2015 to April 2016, ERC using N‐short DBE (DB‐ERC) was performed in 100 postoperative patients (112 procedures). We retrospectively studied the success rate of reaching the blind end, the median time to reach the blind end, the diagnostic success rate, the therapeutic success rate, the median time to complete ERC‐related interventions, the overall success rate, the median time to complete DB‐ERC, and adverse events. Results: The success rate of reaching the blind end was 99.1%. The median time to reach the blind end was 10 min (interquartile range [IQR], 6–19 min). The diagnostic success rate was 98.2%. The therapeutic success rate was 100%. The median time to complete ERC‐related interventions was 36 min (IQR, 22–62 min). The overall DB‐ERC success rate was 97.3%. The median time to complete DB‐ERC was 54 min (IQR, 37–73 min). The occurrence of adverse events was 2.7%. Conclusions: The N‐short DBE for ERC in postoperative patients is useful and safe. DB‐ERC is promising therapeutic modality in such patients and should be selected as the first‐line policy. … (more)
- Is Part Of:
- Journal of gastroenterology and hepatology. Volume 32:Issue 7(2017)
- Journal:
- Journal of gastroenterology and hepatology
- Issue:
- Volume 32:Issue 7(2017)
- Issue Display:
- Volume 32, Issue 7 (2017)
- Year:
- 2017
- Volume:
- 32
- Issue:
- 7
- Issue Sort Value:
- 2017-0032-0007-0000
- Page Start:
- 1348
- Page End:
- 1354
- Publication Date:
- 2017-06-22
- Subjects:
- DBE‐assisted ERC -- endoscopic retrograde cholangiography (ERC) -- Roux‐en‐Y reconstruction -- short‐type double‐balloon endoscopy (DBE)
Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
Liver -- Diseases -- Periodicals
Gastroenterology -- Periodicals
Liver Diseases -- Periodicals
616.33 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1440-1746 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/loi/jgh ↗ - DOI:
- 10.1111/jgh.13713 ↗
- Languages:
- English
- ISSNs:
- 0815-9319
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4987.615000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2881.xml