Efficiency and safety of bivalirudin in patients undergoing emergency percutaneous coronary intervention via radial access: A subgroup analysis from the bivalirudin in acute myocardial infarction versus heparin and GPI plus heparin trial. Issue 7 (28th September 2016)
- Record Type:
- Journal Article
- Title:
- Efficiency and safety of bivalirudin in patients undergoing emergency percutaneous coronary intervention via radial access: A subgroup analysis from the bivalirudin in acute myocardial infarction versus heparin and GPI plus heparin trial. Issue 7 (28th September 2016)
- Main Title:
- Efficiency and safety of bivalirudin in patients undergoing emergency percutaneous coronary intervention via radial access: A subgroup analysis from the bivalirudin in acute myocardial infarction versus heparin and GPI plus heparin trial
- Authors:
- Wang, Heyang
Li, Yi
Cong, Hongliang
Ding, Shifang
Liu, Bin
Li, Lu
Chen, Yundai
Jia, Shaobin
Jing, Quanmin
Zhao, Xin
Liu, Haiwei
Liang, Zhenyang
Li, Jing
Bao, Dan
Han, Yaling - Abstract:
- Abstract : Objectives: To explore the efficiency and safety of bivalirudin in patients undergoing emergency percutaneous coronary intervention via radial access. Background: Bivalirudin reduces bleeding risks over heparin in patients undergoing PCI. However, bleeding advantages of bivalirudin in patients undergoing transradial intervention is uncertain. Methods: In the BRIGHT trial, 1, 723 patients underwent emergency PCI via radial access, with 576 patients in the bivalirudin arm, 576 in the heparin arm and 571 in the heparin plus tirofiban arm. The primary outcome was 30‐day net adverse clinical event (NACE), defined as a composite of major cardiac and cerebral events or any bleeding. Results: 30‐day NACE occurred in 5.7% with bivalirudin, 7.8% with heparin alone (vs. bivalirudin, P = 0.159), and 10.3% with heparin plus tifofiban (vs. bivalirudin, P = 0.004). The 30‐day bleeding rate was 0.9% for bivalirudin, 2.3% for heparin (vs. bivalirudin, P = 0.057), and 5.8% for heparin plus tirofiban (vs. bivalirudin, P < 0.001). Major cardiac and cerebral events (4.9 vs. 5.7 vs. 4.6%, P = 0.899), stent thrombosis (0.5 vs. 0.5 vs. 0.7%, P = 0.899) and acquired thrombocytopenia (0.2 vs. 0.5 vs. 0.9%, P = 0.257) at 30 days were similar among three arms. The interaction test for PCI access and randomized treatment showed no significance on all bleeding ( P > 0.05). Conclusions: The bleeding benefit of bivalirudin was independent of artery access. Bivalirudin lead to statisticalAbstract : Objectives: To explore the efficiency and safety of bivalirudin in patients undergoing emergency percutaneous coronary intervention via radial access. Background: Bivalirudin reduces bleeding risks over heparin in patients undergoing PCI. However, bleeding advantages of bivalirudin in patients undergoing transradial intervention is uncertain. Methods: In the BRIGHT trial, 1, 723 patients underwent emergency PCI via radial access, with 576 patients in the bivalirudin arm, 576 in the heparin arm and 571 in the heparin plus tirofiban arm. The primary outcome was 30‐day net adverse clinical event (NACE), defined as a composite of major cardiac and cerebral events or any bleeding. Results: 30‐day NACE occurred in 5.7% with bivalirudin, 7.8% with heparin alone (vs. bivalirudin, P = 0.159), and 10.3% with heparin plus tifofiban (vs. bivalirudin, P = 0.004). The 30‐day bleeding rate was 0.9% for bivalirudin, 2.3% for heparin (vs. bivalirudin, P = 0.057), and 5.8% for heparin plus tirofiban (vs. bivalirudin, P < 0.001). Major cardiac and cerebral events (4.9 vs. 5.7 vs. 4.6%, P = 0.899), stent thrombosis (0.5 vs. 0.5 vs. 0.7%, P = 0.899) and acquired thrombocytopenia (0.2 vs. 0.5 vs. 0.9%, P = 0.257) at 30 days were similar among three arms. The interaction test for PCI access and randomized treatment showed no significance on all bleeding ( P > 0.05). Conclusions: The bleeding benefit of bivalirudin was independent of artery access. Bivalirudin lead to statistical reduction on bleeding risks in comparison to heparin plus tirofiban, and only small numerical difference in comparison to heparin, with comparable risks of ischemic events and stent thrombosis in patients with acute myocardial infarction (AMI) undergoing emergency transradial PCI. © 2016 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 89:Issue 7(2017)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 89:Issue 7(2017)
- Issue Display:
- Volume 89, Issue 7 (2017)
- Year:
- 2017
- Volume:
- 89
- Issue:
- 7
- Issue Sort Value:
- 2017-0089-0007-0000
- Page Start:
- 1157
- Page End:
- 1165
- Publication Date:
- 2016-09-28
- Subjects:
- bivalirudin -- transradial intervention -- acute myocardial infarction
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.26804 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1836.xml