Characterization of a series of absolute isotope reference materials for magnesium: ab initio calibration of the mass spectrometers, and determination of isotopic compositions and relative atomic weights. Issue 7 (20th May 2016)
- Record Type:
- Journal Article
- Title:
- Characterization of a series of absolute isotope reference materials for magnesium: ab initio calibration of the mass spectrometers, and determination of isotopic compositions and relative atomic weights. Issue 7 (20th May 2016)
- Main Title:
- Characterization of a series of absolute isotope reference materials for magnesium: ab initio calibration of the mass spectrometers, and determination of isotopic compositions and relative atomic weights
- Authors:
- Vogl, Jochen
Brandt, Björn
Noordmann, Janine
Rienitz, Olaf
Malinovskiy, Dmitriy - Abstract:
- Abstract : Three different MC-ICPMS instruments were calibrated by means of synthetic isotope mixtures to enable absolute Mg isotope ratios with expanded uncertainties of ≤0.15‰. Abstract : For the first time, an ab initio calibration for absolute Mg isotope ratios was carried out, without making any a priori assumptions. All quantities influencing the calibration such as the purity of the enriched isotopes or liquid and solid densities were carefully analysed and their associated uncertainties were considered. A second unique aspect was the preparation of three sets of calibration solutions, which were applied to calibrate three multicollector ICPMS instruments by quantifying the correction factors for instrumental mass discrimination. Those fully calibrated mass spectrometers were then used to determine the absolute Mg isotope ratios in three candidate European Reference Materials (ERM)-AE143, -AE144 and -AE145, with ERM-AE143 becoming the new primary isotopic reference material for absolute isotope ratio and delta measurements. The isotope amount ratios of ERM-AE143 are n ( 25 Mg)/ n ( 24 Mg) = 0.126590(20) mol mol −1 and n ( 26 Mg)/ n ( 24 Mg) = 0.139362(43) mol mol −1, with the resulting isotope amount fractions of x ( 24 Mg) = 0.789920(46) mol mol −1, x ( 25 Mg) = 0.099996(14) mol mol −1 and x ( 26 Mg) = 0.110085(28) mol mol −1 and an atomic weight of A r (Mg) = 24.305017(73); all uncertainties were stated for k = 2. This isotopic composition is identical withinAbstract : Three different MC-ICPMS instruments were calibrated by means of synthetic isotope mixtures to enable absolute Mg isotope ratios with expanded uncertainties of ≤0.15‰. Abstract : For the first time, an ab initio calibration for absolute Mg isotope ratios was carried out, without making any a priori assumptions. All quantities influencing the calibration such as the purity of the enriched isotopes or liquid and solid densities were carefully analysed and their associated uncertainties were considered. A second unique aspect was the preparation of three sets of calibration solutions, which were applied to calibrate three multicollector ICPMS instruments by quantifying the correction factors for instrumental mass discrimination. Those fully calibrated mass spectrometers were then used to determine the absolute Mg isotope ratios in three candidate European Reference Materials (ERM)-AE143, -AE144 and -AE145, with ERM-AE143 becoming the new primary isotopic reference material for absolute isotope ratio and delta measurements. The isotope amount ratios of ERM-AE143 are n ( 25 Mg)/ n ( 24 Mg) = 0.126590(20) mol mol −1 and n ( 26 Mg)/ n ( 24 Mg) = 0.139362(43) mol mol −1, with the resulting isotope amount fractions of x ( 24 Mg) = 0.789920(46) mol mol −1, x ( 25 Mg) = 0.099996(14) mol mol −1 and x ( 26 Mg) = 0.110085(28) mol mol −1 and an atomic weight of A r (Mg) = 24.305017(73); all uncertainties were stated for k = 2. This isotopic composition is identical within uncertainties to those stated on the NIST SRM 980 certificate. The candidate materials ERM-AE144 and -AE145 are isotopically lighter than ERM-AE143 by −1.6‰ and −1.3‰, respectively, concerning their n ( 26 Mg)/ n ( 24 Mg) ratio. The relative combined standard uncertainties are ≤0.1‰ for the isotope ratio n ( 25 Mg)/ n ( 24 Mg) and ≤0.15‰ for the isotope ratio n ( 26 Mg)/ n ( 24 Mg). In addition to characterizing the new isotopic reference materials, it was demonstrated that commonly used fractionation laws are invalid for correcting Mg isotope ratios in multicollector ICPMS as they result in a bias which is not covered by its associated uncertainty. Depending on their type, fractionation laws create a bias up to several per mil, with the exponential law showing the smallest bias between 0.1‰ and 0.7‰. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 31:Issue 7(2016:Jul.)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 31:Issue 7(2016:Jul.)
- Issue Display:
- Volume 31, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 7
- Issue Sort Value:
- 2016-0031-0007-0000
- Page Start:
- 1440
- Page End:
- 1458
- Publication Date:
- 2016-05-20
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6ja00013d ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1212.xml