A novel capillary microplasma analytical system: interface-free coupling of glow discharge optical emission spectrometry to capillary electrophoresis. Issue 7 (19th May 2016)
- Record Type:
- Journal Article
- Title:
- A novel capillary microplasma analytical system: interface-free coupling of glow discharge optical emission spectrometry to capillary electrophoresis. Issue 7 (19th May 2016)
- Main Title:
- A novel capillary microplasma analytical system: interface-free coupling of glow discharge optical emission spectrometry to capillary electrophoresis
- Authors:
- Jiang, Xue
Xu, Xinliang
Hou, Xiandeng
Long, Zhou
Tian, Yunfei
Jiang, Xiaoming
Xu, Fujian
Zheng, Chengbin - Abstract:
- Abstract : Interface-free coupling of glow discharge to capillary electrophoresis by sharing one d.c. power supply for elemental and speciation analysis. Abstract : It was found that a capillary electrophoresis (CE) process can be induced by starting a low-temperature d.c. liquid-electrode glow discharge (GD). A novel capillary microplasma analytical system (C-μPAS) was constructed by interface-free coupling of d.c. glow discharge optical emission spectrometry (GD-OES) to CE and was applied in elemental (speciation) analysis. A GD was generated at one end of a capillary, and initiated not only a capillary electrophoresis process but also a microplasma; a sample was injected at the other end of the capillary, separated by CE, and detected by GD-OES. This portable C-μPAS integrates introduction of the sample, separation of the analyte species, and detection of the analytical signal into one unit. The performance of this new analytical system was first evaluated by the analysis of a mixed aqueous solution of mercury, cadmium, chromium, sodium and organic or inorganic species without derivatization, and the absolute limits of detection (LODs) were found to be in the range of 0.5 to 500 picograms under the optimized experimental conditions. Preliminary experimental results for mercury speciation showed that it provided effective separation and results as accurate as those obtained by HPLC-ICP-MS. The working mechanism of this system is discussed, with the theoretically calculatedAbstract : Interface-free coupling of glow discharge to capillary electrophoresis by sharing one d.c. power supply for elemental and speciation analysis. Abstract : It was found that a capillary electrophoresis (CE) process can be induced by starting a low-temperature d.c. liquid-electrode glow discharge (GD). A novel capillary microplasma analytical system (C-μPAS) was constructed by interface-free coupling of d.c. glow discharge optical emission spectrometry (GD-OES) to CE and was applied in elemental (speciation) analysis. A GD was generated at one end of a capillary, and initiated not only a capillary electrophoresis process but also a microplasma; a sample was injected at the other end of the capillary, separated by CE, and detected by GD-OES. This portable C-μPAS integrates introduction of the sample, separation of the analyte species, and detection of the analytical signal into one unit. The performance of this new analytical system was first evaluated by the analysis of a mixed aqueous solution of mercury, cadmium, chromium, sodium and organic or inorganic species without derivatization, and the absolute limits of detection (LODs) were found to be in the range of 0.5 to 500 picograms under the optimized experimental conditions. Preliminary experimental results for mercury speciation showed that it provided effective separation and results as accurate as those obtained by HPLC-ICP-MS. The working mechanism of this system is discussed, with the theoretically calculated electron temperature and electron density of the microplasma. This C-μPAS has the advantages of portable instrumentation, green chemistry (low power consumption, tiny sampling volume and almost no pollutants), high sensitivity (detection of optical emissions), low interference (separation by CE and spectral resolution), versatility (organic, inorganic, cationic or anionic analytes), and fast analysis (several minutes). It should have a very promising future in a range of areas such as environmental analysis, metallomics research, water analysis, online monitoring and field analytical chemistry. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 31:Issue 7(2016:Jul.)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 31:Issue 7(2016:Jul.)
- Issue Display:
- Volume 31, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 7
- Issue Sort Value:
- 2016-0031-0007-0000
- Page Start:
- 1423
- Page End:
- 1429
- Publication Date:
- 2016-05-19
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6ja00142d ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1213.xml