Method comparison and generation of plasma biochemistry RIs for the White rhinoceros on a point‐of‐care and wet chemistry analyzer. (17th April 2017)
- Record Type:
- Journal Article
- Title:
- Method comparison and generation of plasma biochemistry RIs for the White rhinoceros on a point‐of‐care and wet chemistry analyzer. (17th April 2017)
- Main Title:
- Method comparison and generation of plasma biochemistry RIs for the White rhinoceros on a point‐of‐care and wet chemistry analyzer
- Authors:
- Hooijberg, Emma H.
Steenkamp, Gerhard
Buss, Peter
Goddard, Amelia - Abstract:
- Abstract : Background: Plasma biochemistry analysis may aid the management of White rhinoceros with poaching or other injuries. Analyzer‐ and species‐specific RIs are necessary to evaluate health status and identify abnormalities. Objectives: The purpose of the study was to perform a comparison study between the IDEXX VetTest and Roche Cobas Integra 400 Plus, and to generate analyzer‐specific RIs for White rhinoceros according to published guidelines. Methods: Comparison was carried out using White rhinoceros plasma samples from healthy and diseased animals. Reference intervals for albumin, ALT, AST, CK, creatinine, GGT, globulins, glucose, phosphorus, total proteins, and urea were determined from a sample group of chemically immobilized healthy adult White rhinoceros from the Kruger National Park, South Africa. Results: There was a significant analytic bias for all analytes between the 2 analyzers. Results for glucose and total protein were clinically equivalent based on total allowable error limits. Reference intervals were generated from 51 individuals (26 male, 25 female) for all analytes except ALT on the VetTest. Discussion: The type, direction, and magnitude of bias between the VetTest and Cobas appeared to be species‐ and analyzer‐specific, when compared to other studies. These measures of bias may be used for comparability testing. Reference intervals for total proteins (VetTest 77–108 g/L, Cobas 77–110 g/L) and globulins (VetTest 47–79 g/L, Cobas 51–87 g/L) wereAbstract : Background: Plasma biochemistry analysis may aid the management of White rhinoceros with poaching or other injuries. Analyzer‐ and species‐specific RIs are necessary to evaluate health status and identify abnormalities. Objectives: The purpose of the study was to perform a comparison study between the IDEXX VetTest and Roche Cobas Integra 400 Plus, and to generate analyzer‐specific RIs for White rhinoceros according to published guidelines. Methods: Comparison was carried out using White rhinoceros plasma samples from healthy and diseased animals. Reference intervals for albumin, ALT, AST, CK, creatinine, GGT, globulins, glucose, phosphorus, total proteins, and urea were determined from a sample group of chemically immobilized healthy adult White rhinoceros from the Kruger National Park, South Africa. Results: There was a significant analytic bias for all analytes between the 2 analyzers. Results for glucose and total protein were clinically equivalent based on total allowable error limits. Reference intervals were generated from 51 individuals (26 male, 25 female) for all analytes except ALT on the VetTest. Discussion: The type, direction, and magnitude of bias between the VetTest and Cobas appeared to be species‐ and analyzer‐specific, when compared to other studies. These measures of bias may be used for comparability testing. Reference intervals for total proteins (VetTest 77–108 g/L, Cobas 77–110 g/L) and globulins (VetTest 47–79 g/L, Cobas 51–87 g/L) were high compared to other uneven‐toed ungulates. Conclusion: Plasma samples from White rhinoceros can be evaluated on both the VetTest and Cobas. Results from this study will aid conservation efforts directed toward this species. … (more)
- Is Part Of:
- Veterinary clinical pathology. Volume 46:Number 2(2017)
- Journal:
- Veterinary clinical pathology
- Issue:
- Volume 46:Number 2(2017)
- Issue Display:
- Volume 46, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 2
- Issue Sort Value:
- 2017-0046-0002-0000
- Page Start:
- 287
- Page End:
- 298
- Publication Date:
- 2017-04-17
- Subjects:
- Ceratotherium simum -- clinical chemistry -- Cobas Integra -- protein -- VetTest
Veterinary pathology -- Periodicals
636.089607 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/vcp.12490 ↗
- Languages:
- English
- ISSNs:
- 0275-6382
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9227.015500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1493.xml