Effect of spatial separation and noise type on sentence recognition by Mandarin-speaking cochlear implant users. (3rd August 2017)
- Record Type:
- Journal Article
- Title:
- Effect of spatial separation and noise type on sentence recognition by Mandarin-speaking cochlear implant users. (3rd August 2017)
- Main Title:
- Effect of spatial separation and noise type on sentence recognition by Mandarin-speaking cochlear implant users
- Authors:
- Liu, Yang-Wenyi
Tao, Duo-Duo
Jiang, Ye
GalvinIII, John J.
Fu, Qian-Jie
Yuan, Ya-sheng
Chen, Bing - Abstract:
- Abstract: Objectives: To investigate the effects of spatial separation and noise type on sentence recognition by unilateral Mandarin-speaking cochlear implant (CI) users and normal-hearing (NH) listeners. Method : Twenty-two unilateral Mandarin-speaking CI users and six NH listeners participated in this study. Speech reception thresholds were measured for three noise types (steady state noise, speech babble, and music). Sentences from the Mandarin Speech Perception test were presented directly in front of the listener (0°). Noise was presented from one of the five speaker locations: −90°, −45°, 0°, +45°, and +90°. Results : Overall, CI performance was significantly poorer than NH performance for all spatial separation and noise type conditions. NH listeners performed best with music and poorest with steady noise. CI users performed best with steady noise, and poorest with babble. Performance was significantly affected by noise location and noise type. There was no significant difference in head shadow effects among the different noise types for CI users. Conclusions: Performance was much poorer in CI than in NH listeners for all noise types and spatial separations. Noise type differently affected unilateral CI users and NH listeners. The limited spectral resolution in CI users did not appear to affect head shadow.
- Is Part Of:
- Acta oto-laryngologica. Volume 137:Number 8(2017)
- Journal:
- Acta oto-laryngologica
- Issue:
- Volume 137:Number 8(2017)
- Issue Display:
- Volume 137, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 137
- Issue:
- 8
- Issue Sort Value:
- 2017-0137-0008-0000
- Page Start:
- 829
- Page End:
- 836
- Publication Date:
- 2017-08-03
- Subjects:
- Cochlear implant -- speech perception -- head shadow effect -- noise
Otolaryngology -- Periodicals
Ear -- Diseases -- Periodicals
Throat -- Diseases -- Periodicals
Otolaryngology -- Electronic Resources
Otorhinolaryngologic Diseases
617.8 - Journal URLs:
- http://www.tandfonline.com/loi/ioto20#.V6CqjFJTHcs ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00016489.2017.1292050 ↗
- Languages:
- English
- ISSNs:
- 0001-6489
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0642.250000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 752.xml