Diagnostic efficacy and safety of gadoteric acid MR mammography in 1537 patients. Issue 12 (December 2016)
- Record Type:
- Journal Article
- Title:
- Diagnostic efficacy and safety of gadoteric acid MR mammography in 1537 patients. Issue 12 (December 2016)
- Main Title:
- Diagnostic efficacy and safety of gadoteric acid MR mammography in 1537 patients
- Authors:
- Seithe, Tim
Braun, Joachim
Wolf, Michael
Vahldiek, Janis
Wolny, Dajana
Auer, Jonas
Pociej, Joanna
Heine, Oliver
Hamm, Bernd
de Bucourt, Maximilian - Abstract:
- Abstract: Objectives: To perform a large-scale multicenter post-marketing surveillance study for analyzing diagnostic effectiveness and safety of intravenous (IV) gadoteric acid (Dotarem ® ) in magnetic resonance (MR) mammography under daily practice conditions. Materials and methods: Patients underwent high-resolution MR mammography with gadoteric acid in 15 German centers. Radiologists used a standardized questionnaire to report data including patient demographics and medical history, characteristics of MR examination and results in terms of diagnosis and safety for the patient. Results: A total of 1537 patients were examined. In 99.2% of all patients, a diagnosis was established. In 91.6% of all patients, image quality was excellent or good. Histopathological examinations were performed for 232 of 1537 patients (15.1%) with invasive ductal carcinoma being the most frequent diagnosis (109 patients, 47.0%). Based on histopathology as the standard of reference, IV gadoteric acid-enhanced MR mammography confirmed diagnoses of invasive ductal carcinoma in 93.5% of the patients. Adverse drug reactions occurred in 5 of 1537 patients (0.3%) and were classified as serious in one case (tachycardia, dysphagia, urticaria, rash). All patients with adverse drug reactions fully recovered after the examination. Conclusion: This noninterventional surveillance study shows IV gadoteric acid to be a safe and effective contrast agent for use in MR mammography.
- Is Part Of:
- European journal of radiology. Volume 85:Issue 12(2016)
- Journal:
- European journal of radiology
- Issue:
- Volume 85:Issue 12(2016)
- Issue Display:
- Volume 85, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 85
- Issue:
- 12
- Issue Sort Value:
- 2016-0085-0012-0000
- Page Start:
- 2281
- Page End:
- 2287
- Publication Date:
- 2016-12
- Subjects:
- MR mammography -- Gadoteric acid -- Gadoterate meglumine -- Post-marketing surveillance -- Efficacy -- Adverse drug reactions
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2016.10.013 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1273.xml