Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications. Issue 12 (December 2016)
- Record Type:
- Journal Article
- Title:
- Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications. Issue 12 (December 2016)
- Main Title:
- Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications
- Authors:
- Clauser, Paola
Nagl, Georg
Helbich, Thomas H.
Pinker-Domenig, Katja
Weber, Michael
Kapetas, Panagiotis
Bernathova, Maria
Baltzer, Pascal A.T. - Abstract:
- Highlights: Wide scan-angle DBT alone shows a high detection rate for microcalcifications. DBT and FFDM can characterize microcalcifications at a comparable level. Characterization is influenced by reader and by lesion type (benign vs malignant). DBT might be used as a stand-alone technique for the assessment of microcalcifications. Abstract: Objectives: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications. Methods: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients' history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions' characteristics and reading time were analysed. Results: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P = 0.510). Inter-reader differences were detected (P < 0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-readerHighlights: Wide scan-angle DBT alone shows a high detection rate for microcalcifications. DBT and FFDM can characterize microcalcifications at a comparable level. Characterization is influenced by reader and by lesion type (benign vs malignant). DBT might be used as a stand-alone technique for the assessment of microcalcifications. Abstract: Objectives: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications. Methods: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients' history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions' characteristics and reading time were analysed. Results: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P = 0.510). Inter-reader differences were detected (P < 0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P = 0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25 s, respectively). Conclusion: Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen. … (more)
- Is Part Of:
- European journal of radiology. Volume 85:Issue 12(2016)
- Journal:
- European journal of radiology
- Issue:
- Volume 85:Issue 12(2016)
- Issue Display:
- Volume 85, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 85
- Issue:
- 12
- Issue Sort Value:
- 2016-0085-0012-0000
- Page Start:
- 2161
- Page End:
- 2168
- Publication Date:
- 2016-12
- Subjects:
- Breast cancer -- Mammography -- Microcalcifications -- Digital breast tomosynthesis -- Comparative studies
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2016.10.004 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1273.xml