New web-based algorithm to improve rigid gas permeable contact lens fitting in keratoconus. Issue 3 (June 2017)
- Record Type:
- Journal Article
- Title:
- New web-based algorithm to improve rigid gas permeable contact lens fitting in keratoconus. Issue 3 (June 2017)
- Main Title:
- New web-based algorithm to improve rigid gas permeable contact lens fitting in keratoconus
- Authors:
- Ortiz-Toquero, Sara
Rodriguez, Guadalupe
de Juan, Victoria
Martin, Raul - Abstract:
- Highlights: The fitting of GP lenses in keratoconus is challenging for eye care practitioners. A new algorithm is developed to select the initial diagnostic lens in keratoconus. This algorithm is included in the websitewww.calculens.com . Calculens improves the results provided by the manufacturer and software fitting. Calculens will reduce practitioner and patient chair time in keratoconus GP fittings. Abstract: Purpose: To calculate and validate a new web-based algorithm for selecting the back optic zone radius (BOZR) of spherical gas permeable (GP) lens in keratoconus eyes. Methods: A retrospective calculation (n = 35; multiple regression analysis) and a posterior prospective validation (new sample of 50 keratoconus eyes) of a new algorithm to select the BOZR of spherical KAKC design GP lenses (Conoptica) in keratoconus were conducted. BOZR calculated with the new algorithm, manufacturer guidelines and APEX software were compared with the BOZR that was finally prescribed. Number of diagnostic lenses, ordered lenses and visits to achieve optimal fitting were recorded and compared those obtained for a control group [50 healthy eyes fitted with spherical GP (BIAS design; Conoptica)]. Results: The new algorithm highly correlated with the final BOZR fitted (r 2 = 0.825, p < 0.001). BOZR of the first diagnostic lens using the new algorithm demonstrated lower difference with the final BOZR prescribed (-0.01 ± 0.12 mm, p = 0.65; 58% difference ≤ 0.05 mm) than with theHighlights: The fitting of GP lenses in keratoconus is challenging for eye care practitioners. A new algorithm is developed to select the initial diagnostic lens in keratoconus. This algorithm is included in the websitewww.calculens.com . Calculens improves the results provided by the manufacturer and software fitting. Calculens will reduce practitioner and patient chair time in keratoconus GP fittings. Abstract: Purpose: To calculate and validate a new web-based algorithm for selecting the back optic zone radius (BOZR) of spherical gas permeable (GP) lens in keratoconus eyes. Methods: A retrospective calculation (n = 35; multiple regression analysis) and a posterior prospective validation (new sample of 50 keratoconus eyes) of a new algorithm to select the BOZR of spherical KAKC design GP lenses (Conoptica) in keratoconus were conducted. BOZR calculated with the new algorithm, manufacturer guidelines and APEX software were compared with the BOZR that was finally prescribed. Number of diagnostic lenses, ordered lenses and visits to achieve optimal fitting were recorded and compared those obtained for a control group [50 healthy eyes fitted with spherical GP (BIAS design; Conoptica)]. Results: The new algorithm highly correlated with the final BOZR fitted (r 2 = 0.825, p < 0.001). BOZR of the first diagnostic lens using the new algorithm demonstrated lower difference with the final BOZR prescribed (-0.01 ± 0.12 mm, p = 0.65; 58% difference ≤ 0.05 mm) than with the manufacturer guidelines (+0.12 ± 0.22 mm, p < 0.001; 26% difference ≤ 0.05 mm) and APEX software (-0.14 ± 0.16 mm, p = 0.001; 34% difference ≤ 0.05 mm). Close numbers of diagnostic lens (1.6 ± 0.8, 1.3 ± 0.5; p = 0.02), ordered lens (1.4 ± 0.6, 1.1 ± 0.3; P < 0.001), and visits (3.4 ± 0.7, 3.2 ± 0.4; p = 0.08) were required to fit keratoconus and healthy eyes, respectively. Conclusion: This new algorithm (free access atwww.calculens.com ) improves spherical KAKC GP fitting in keratoconus and can reduce the practitioner and patient chair time to achieve a final acceptable fit in keratoconus. This algorithm reduces differences between keratoconus GP fitting (KAKC design) and standard GP (BIAS design) lenses fitting in healthy eyes. … (more)
- Is Part Of:
- Contact lens & anterior eye. Volume 40:Issue 3(2017)
- Journal:
- Contact lens & anterior eye
- Issue:
- Volume 40:Issue 3(2017)
- Issue Display:
- Volume 40, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 40
- Issue:
- 3
- Issue Sort Value:
- 2017-0040-0003-0000
- Page Start:
- 143
- Page End:
- 150
- Publication Date:
- 2017-06
- Subjects:
- Algorithm -- Gas permeable -- Contact lens -- Keratoconus
Anterior segment (Eye) -- Periodicals
Contact lenses -- Periodicals
Segment antérieur (Œil) -- Périodiques
Lentilles de contact -- Périodiques
617.752305 - Journal URLs:
- http://firstsearch.oclc.org/journal=1367-0484;screen=info;ECOIP ↗
http://www.sciencedirect.com/science/journal/13670484 ↗
http://www.contactlensjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13670484 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13670484 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clae.2016.12.009 ↗
- Languages:
- English
- ISSNs:
- 1367-0484
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3424.971000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 319.xml