Numerical investigation of heat transfer and friction factor characteristics from in-line cam shaped tube bank in crossflow. (5th January 2017)
- Record Type:
- Journal Article
- Title:
- Numerical investigation of heat transfer and friction factor characteristics from in-line cam shaped tube bank in crossflow. (5th January 2017)
- Main Title:
- Numerical investigation of heat transfer and friction factor characteristics from in-line cam shaped tube bank in crossflow
- Authors:
- Mangrulkar, Chidanand K.
Dhoble, Ashwinkumar S.
Deshmukh, Amey R.
Mandavgane, Sachin A. - Abstract:
- Highlights: Thermal performance of cam shaped tubes in cross flow is studied numerically. The study is carried out for Reynolds number range from 11, 500 to 42, 500. Heat transfer rate is higher in cam shaped tubes as compared to circular tubes. The friction factor in cam shaped tubes is 85% less as compared to circular tubes. Abstract: Tube bank heat exchangers are considered to be an effective device for heat transfer between two fluids. Researchers investigated various arrangements and along with different geometries of the tube, so as to improve the thermal performance of the tube bank. In the present study, the numerical investigation is carried out to determine the thermal performance of cam shaped tube. The study is performed for the heat transfer and friction factor characteristics in the Reynolds number range from 11, 500 to 42, 500. The result of the numerical simulation indicates the superior thermal performance of the cam shaped tube banks over the circular tubes. As the friction factor is reduced by 85–89% as compared to the circular tubes the heat transfer by friction factor ( Nu /f) is increased by 5 times as compared to circular tubes. However, the efficiency of cam tubes with a pitch ratio of 1.5 is higher than that of the pitch ratio of 2.0. Further, the area goodness factor is also around 9 times higher than circular tubes.
- Is Part Of:
- Applied thermal engineering. Volume 110(2017:Jan.)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 110(2017:Jan.)
- Issue Display:
- Volume 110 (2017)
- Year:
- 2017
- Volume:
- 110
- Issue Sort Value:
- 2017-0110-0000-0000
- Page Start:
- 521
- Page End:
- 538
- Publication Date:
- 2017-01-05
- Subjects:
- Cross flow -- Cam shaped tubes -- Heat transfer
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2016.08.174 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 105.xml