Differentiation of small intrahepatic mass-forming cholangiocarcinoma from small liver abscess by dual source dual-energy CT quantitative parameters. Issue 92 (July 2017)
- Record Type:
- Journal Article
- Title:
- Differentiation of small intrahepatic mass-forming cholangiocarcinoma from small liver abscess by dual source dual-energy CT quantitative parameters. Issue 92 (July 2017)
- Main Title:
- Differentiation of small intrahepatic mass-forming cholangiocarcinoma from small liver abscess by dual source dual-energy CT quantitative parameters
- Authors:
- Kim, Ji Eun
Kim, Hyun Ok
Bae, Kyungsoo
Cho, Jae Min
Choi, Ho Cheol
Choi, Dae Seob - Abstract:
- Highlights: CT values on VMI, k and NIC values were significantly higher in IMCCs than in LAs. The best single parameter for differentiating IMCC from LA was CT value at 90 keV. The best combined parameters for differentiation were CT value at 90 keV, k, and NIC. Quantitative analysis of DECT improves accuracy for differentiating IMCCs from LAs. Abstract: Purpose: To investigate the use of dual source dual-energy CT (DECT) quantitative parameters compared with the use of conventional CT for differentiating small (≤3 cm) intrahepatic mass-forming cholangiocarcinoma (IMCC) from small liver abscess (LA) during the portal venous phase (PVP). Material and methods: In this institutional review board-approved, retrospective study, 64 patients with IMCCs and 52 patients with LAs who were imaged in PVP using dual-energy mode were included retrospectively. A radiologist drew circular regions of interest in the lesion on the virtual monochromatic images (VMI), color-coded iodine overlay images, and linear blending images with a linear blending ratio of 0.3 to obtain CT value, its standard deviation, slope ( k ) of spectral curve and normalized iodine concentration (NIC). Two radiologists assessed lesion type on the basis of qualitative CT imaging features. Results: CT values on VMI at 50–130 keV (20 keV-interval), k, and NIC values were significantly higher in IMCCs than in LAs ( p < 0.0001). The best single parameter for differentiating IMCC from LA was CT value at 90 keV, withHighlights: CT values on VMI, k and NIC values were significantly higher in IMCCs than in LAs. The best single parameter for differentiating IMCC from LA was CT value at 90 keV. The best combined parameters for differentiation were CT value at 90 keV, k, and NIC. Quantitative analysis of DECT improves accuracy for differentiating IMCCs from LAs. Abstract: Purpose: To investigate the use of dual source dual-energy CT (DECT) quantitative parameters compared with the use of conventional CT for differentiating small (≤3 cm) intrahepatic mass-forming cholangiocarcinoma (IMCC) from small liver abscess (LA) during the portal venous phase (PVP). Material and methods: In this institutional review board-approved, retrospective study, 64 patients with IMCCs and 52 patients with LAs who were imaged in PVP using dual-energy mode were included retrospectively. A radiologist drew circular regions of interest in the lesion on the virtual monochromatic images (VMI), color-coded iodine overlay images, and linear blending images with a linear blending ratio of 0.3 to obtain CT value, its standard deviation, slope ( k ) of spectral curve and normalized iodine concentration (NIC). Two radiologists assessed lesion type on the basis of qualitative CT imaging features. Results: CT values on VMI at 50–130 keV (20 keV-interval), k, and NIC values were significantly higher in IMCCs than in LAs ( p < 0.0001). The best single parameter for differentiating IMCC from LA was CT value at 90 keV, with sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 89.1%, 86.5%, 87.9%, 89.1%, and 86.5%, respectively. The best combination of parameters was CT value at 90 keV, k, and NIC, with values of 87.5%, 84.6%, 83.6%, 87.5%, and 84.6%, respectively. Compared with CT value at linear blending images, CT value at 90 keV showed greater sensitivity (89.1% vs 60.9%, p < 0.0001) and similar specificity (86.5% vs 84.6%, p = 1.0000), and combined CT value at 90 keV, k, and NIC showed greater sensitivity (87.5% vs 60.9%, p < 0.0001) and similar specificity (84.6% vs 84.6%, p = 1.0000). Compared with qualitative analysis, CT value at 90 keV showed greater sensitivity (89.1% vs 65.6%, p = 0.0059) and specificity (86.5% vs 69.2%, p = 0.0352), and combined CT value at 90 keV, k, and NIC showed greater sensitivity (87.5% vs 65.6%, p = 0.0094) and similar specificity (84.6% vs 69.2%, p > 0.05). Conclusion: Quantitative analysis of dual source dual-energy CT quantitative parameters showed greater accuracy than quantitative and qualitative analyses of conventional CT for differentiating small IMCCs from small LAs on single PVP scan. … (more)
- Is Part Of:
- European journal of radiology. Issue 92(2017)
- Journal:
- European journal of radiology
- Issue:
- Issue 92(2017)
- Issue Display:
- Volume 92, Issue 92 (2017)
- Year:
- 2017
- Volume:
- 92
- Issue:
- 92
- Issue Sort Value:
- 2017-0092-0092-0000
- Page Start:
- 145
- Page End:
- 152
- Publication Date:
- 2017-07
- Subjects:
- IMCC intrahepatic mass-forming cholangiocarcinoma -- LA liver abscess -- PVP portal venous phase -- DECT dual-energy CT -- VMI virtual monochromatic images -- ROI region of interest -- PACS picture archiving and communications system -- SD standard deviation -- NIC normalized iodine concentration -- ROC receiver operating characteristic -- PPV positive predictive value -- NPV negative predictive value -- CI confidence interval
Intrahepatic cholangiocarcinoma -- Liver abscess -- Computed tomography -- Dual-energy -- Quantitative evaluation
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2017.05.012 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2479.xml